67
Model
GENUS HE 35 Plus
CE certificate
1312-BP-4082
Performance category
****
NoX class
5
Category
II2H3P
Heating output
80°C/60°C
Kw
6 to 30
Heating output
50°C/30°C
Kw
7 to 32
Variable hot water power
Pn max
Kw
35
Nominal gas flow rate
(15 °C-1013 mbar)
min
max
Central Heating & DHW flow rate
Qn
kW
7
31
G 20 (NG H -Lacq)
34,02 MJ/m
3
under 20 mbar
Vr
m
3
/h
0,74
3,28
G 31 (Propane)
46,4 MJ/kg 37 under mbar
Vr
kg/h
0,54
2,41
Membrane
Diameter (mm)/marking
G 20
mm
without
G 31 (propane)
mm
5
Adjustable heating outlet temperature:
°C
25 to 75 or 42 to 82
Central heating minimum flow rate
I/h
300
Central heating circuit maximum pressure
Pw max
bar
3
Central heating expansion vessel capacity
L
7,1
Expansion vessel inflation pressure
bar
0,7
Adjustable hot water temperature
°C
40 to 70
Stored D.H.W. cylinder capacity
L
42
DHW ignition flow rate
l/min.
2
DHW specific flow rate (ΔT: 30 K)
D
I/min.
21,0
DHW start minimum pressure
Pw min
bar
0,3
Maximum pressure of DHW circuit
Pw max
bar
7
DHW expansion vessel
L
4
Electric voltage
230 volt, single phase - 50 Hz
Electrical input power
W
150
Electrical protection
IP44
Fresh air flow rate required for combustion
V
m
3
h.
40
Mass flow rate for combustion products
15,5
Fume temperature (60-80)
°C
67
Fume temperature (30-50)
°C
60
CO2 G20
%
9
CO2 G31
%
10
Dimensions
Height / Width / Depth (mm)
950 / 595 / 470
Weight
kg
59
Flue duct type
C13 C33 C43 C53 B23
SEDBUK
Band
A
This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person.
21.
TECHNICAL INFORMATION