62
NO
NO
NO
NO
YES
YES
POWER TO
THE PUMP?
1 - Check that the pump
is not stuck
2 - Release/replace pump
1 - Check DHW flowswitch
2 - Check pump cable
3 - Check/replace P.C.B.
NO
NO
POWER TO
FAN ?
1 - Check/replace
connection cable
2 - Check/replace P.C.B.
YES
YES
YES
YES
1 - Replace fan
YES
YES
FC P013
NO
NO
IS THE BURNER
ALIGHT?
YES
YES
NO
NO
YES
YES
NO
NO
NO
NO
YES
YES
1 - Check/replace ignition
electrode
2 - Check ignition cable
3 - Check spark generator
4 - Check ignition electrode
cable
5 - Check/replace P.C.B.
1 - Check if flame strikes
detection electrode
2 - Check soft-light gas
pressure
3 - Check/replace detection
electrode
4 - Check/replace P.C.B.
1 - Check power supply of
gas valve
2 - Check/replace P.C.B.
3 - Check efficiency of
gas valve
4 - Replace gas valve
IS SPARK
GENERATION FOR
IGNITION
NORMAL?
HAS THE
BOILER SAFETY
SHUTDOWN BEEN
ACTIVATED?
IS THE FAN
RUNNING?
IS THE PUMP
RUNNING?
A
B