41
F
F
Selection of Secondary Output operation
E
Only activated if peripheral interface card connected (option)
For connection of peripherals to the motherboard, refer to the user
instructions for the Clima Manager or the external sensor. Parameter E
is altered by the
and
programming buttons.
00
Zone valve - factory setting
01
NOT USED
02
NOT USED
03
NOT USED
Circulation pump post-circulation
P
The appliance allows variation of the post-circulation period of the
circulation pump after extinction of the burner. Adjustable from 1 to 15
minutes or continuous (
CO
).
Use the
and
buttons in menu
P
to select the required value.
The factory-set value is given in the menu table.
Comfort Function : activation/deactivation of the Domestic hot
water and tank reheating functions
C
00
Domestic hot water and tank reheating functions deactivated
01
Domestic hot water and tank reheating functions activated
When the function is activated, the yellow indicator light
31
comes on.
To deactivate the
Comfort
function, press the
button.
The yellow indicator light
31
goes out.
Use the
and
buttons in menu
C
to select the required value.
The factory-set value is given in the menu table.
COMFORT
Circulation pump speed
P
U0
- Fixed speed operation
U1
- Variable speed operation
Use the
and
buttons in menu
P
to select the required value.
The factory-set value is given in the menu table.
Heating temperature range setting
r
00
- possibility of adjusting the temperature from 25°C to x in menu
4
possibility of adjusting the temperature from x+1 to 75°C in menu
5
where x ≤ 44 °C
01
- possibility of adjusting the temperature from 42°C to y in menu
4
- possibility of adjusting the temperature from y+1 to 82°C in menu
5
where y ≤ 81 °C
Use the
and
buttons in menu
r
to select the required value.
The factory-set value is given in the menu table.
Temperature control by external sensor
P
(Only activated if the external sensor is installed)
“
90
” Temperature adjustment by external sensor deactivated (external
sensor not installed).
“
91
” Temperature adjustment by external sensor activated (external
sensor installed).
Use the
and
buttons in menu
P
to select the required value.
The factory-set value is given in the menu table.