Technical Data
GEN. NO
TES
Model Name
CLAS EVO 24 CF
CLAS EVO
SYSTEM 24 CF
CLAS EVO
SYSTEM 28 CF
CE certifi cation (pin)
1312BR4794
1312BR4923
Boiler type
B11 - B11bs
ELEC
TRICAL PERFORM
ANCE
Max/min nominal heat input(Hi)
kW
25,8 / 11,0
25,8 / 11,0
29,5 / 13,0
Max/min nominal heat input (Hs)
kW
28,7 / 12,2
28,7 / 12,2
32,8 / 14,4
Max/min nominal heat input for hot water (Hi)
kW
27 / 11,0
27 / 11,0
30,5 / 13
Max/min nominal heat input for hot water (Hs)
kW
30 / 12,2
30 / 12,2
33,9 / 14,4
Heat output: max/min
kW
23,7 / 9,9
23,7 / 9,9
26,7 / 11,2
D.H.W. Heat output: max/min
kW
24,8 / 99
24,8 / 99
27,6 / 11,2
Combustion effi
ciency (at fl ue) Hi/Hs
%
93,0
93,0
92,3
Gross effi
ciency of nominal heat input (60/80 °C) Hi/Hs
%
91,9 / 82,8
91,9 / 82,8
90,6 / 81,6
Gross effi
ciency at 30 % at 47°C Hi/Hs
%
91,2 / 82,1
91,2 / 82,1
89,7 / 80,8
Gross effi
ciency at minimum power Hi/Hs
%
90,2 / 81,2
90,2 / 81,2
86,5 / 77,9
Number of effi
ciency stars (Directive 92/42/EEC)
stars
***
***
**
Rating Sedbuk
class
D
D
D
Ma. heat loss to the casing (ΔT = 50°C)
%
1,1
1,1
1,7
Heat loss through the fl ue when burner on
% 7,0
7,0
7,7
Heat loss through the fl ue when burner off %
0,4
0,4
0,4
EMISSIONS
Residual discharge head
Pa
3
3
3
Nox class
class
3
3
3
Flue fumes temperature (G20)
°C
118
118
133
CO2 content
2
(G20)
%
5,8
5,8
6,2
CO content (0 %0
2
)
ppm
53
53
41
O2 content2
(G20)
%
10,1
10,1
9,3
Max capacity fumes (G20)
kg/h
63,6
63,6
68,9
Excess air
%
93
93
80
HEA
TING CIRCUIT
Load losses water side (max) ΔT=20°C
(mbar)
200
200
200
Residual head for the system
bar
0,25
0,25
0,25
Expansion vessel pre-charged pressure
bar
1
1
1
Maximum central heating circuit pressure
bar
3
3
3
Expansion vessel capacity
l
8
8
8
Central heating temperature: max/min(high temperature
range)
°C
82 / 35
82 / 35
82 / 35
DOMESTIC HO
T
W
A
TER CIRCUIT
Domestic hot water temperature max/min
°C
60 / 36
60 / 40
60 / 40
Specifi c fl ow rate of domestic hot water system (10 min. with
ΔT=30°C)) instant boilers
l/min
12,2
D.H.W. fl ow rate ΔT=25°C
l/min
14.5
D.H.W. fl ow rater ΔT=35°C
l/min
10,2
Hot water comfort stars (EN13203)
stars
3
D.H.W. minimum fl ow rate
l/min
1,7
Domestic hot water pressure max/min
bar
7
ROOMELEC
TRICAL
DA
TA
Power supply voltage/frequency
V/Hz
230/50
230/50
230/50
Power consumption
W
79
79
90
Minimum operating room temperature
°C
+5
+5
+5
Electric system grades of protection
IP
X5D
X5D
X5D
Weight
kg
30
30
31