Appendix A: Status Indicators
Power Supply Status Indicators
Quick Start Guide: 7300 Series Modular Data Center Switches
35
Figure A-4: Power Supply
interprets the states of the Power Supply Status LED.
Table A-7 Power Supply Status
AC OK LED
Fault LED
DC OK LED
Status
Green
Off
Green
Power Supply module operating normally.
Green
Off
Off
AC is present, Main output is off.
Off
Off
Off
No AC power to the module.
Green
Amber Blinking
Off
Module has failed.