![Arista DCS-7304 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/arista/dcs-7304/dcs-7304_quick-start-manual_2970783027.webp)
Chapter 4: Powering the Modular Switch
Cabling the DC Power Supply
Quick Start Guide: 7300 Series Modular Data Center Switches
23
Step 2
Remove the Flange locking nuts from each of the terminal studs.
Figure 4-6: Remove the Flange locking nuts from each terminal stud
Step 3
Secure each power cable lug to the terminal studs with the Flange locking nuts.
•
Attach the positive (+) DC source power cable lug to the RTN (return) terminal.
•
Attach the negative (–) DC source power cable lug to the –48V (input) terminal.
•
Torque the two Flange locking nuts to 5.1 N•m (45 in. lbs.).
Figure 4-7: Attaching the cables to the terminal studs
Figure 4-8: Securing the cable lugs to the terminal studs with the Flange nuts