34
Quick Start Guide: 7300 Series Modular Data Center Switches
Power Supply Status Indicators
Appendix A: Status Indicators
Figure A-3: Fan Status and Fabric Status LEDs
The
fan module installation indicator
is green when the fan module is properly installed or red when
the module is not fully installed.
interprets the states of the Fan and Fabric Status LEDs.
A.4
Power Supply Status Indicators
Power Supply LEDs are on power supply modules. The front panel contains power supply modules for
all switches; the DCS-7316 rear panel may also contain power supply modules.
(front
panels) and
(rear panels) displays the position of these LEDs on each switch.
display a power supply module.
The power supply handle indicates the power supply fan direction. Verify the airflow direction of all
modules satisfy these criteria:
•
All rear panel modules (fan and power supply modules) have the same color handles.
•
All front panel modules (power supply modules) have the same color handles.
•
Rear panel modules and front panel modules have different color handles.
Table A-6 Fan and Fabric Status LED States
LED State
Status
Off
The module is inserted but not receiving power – it may not be properly seated.
Green
The module is operating normally.
Red
The module has failed.
Содержание DCS-7304
Страница 10: ...6 Quick Start Guide 7300 Series Modular Data Center Switches Specifications Chapter 1 Overview ...
Страница 48: ...44 Quick Start Guide 7300 Series Modular Data Center Switches Two Post Rack Mount Parts Appendix C Parts List ...
Страница 52: ...48 Quick Start Guide 7300 Series Modular Data Center Switches Appendix D Front Panels ...
Страница 55: ...Appendix E Rear Panels Quick Start Guide 7300 Series Modular Data Center Switches 51 DCS 7316 Rear Panel ...
Страница 56: ...52 Quick Start Guide 7300 Series Modular Data Center Switches Appendix E Rear Panels ...
Страница 58: ...54 Quick Start Guide 7300 Series Modular Data Center Switches Appendix F Line Cards DCS 7320X 32C LC ...