1.0    Important Safeguards

                                                            

When using this electrical appliance, basic safety precautions should always be followed including the

following:

  READ ALL INSTRUCTIONS before use.

  Follow all 

WARNINGS

 and 

INSTRUCTIONS

 marked on the product.

 

DO NOT

 immerse appliance in water or other liquid.   Use a soft cloth and mild detergent when

cleaning  the  unit.

 

DO NOT

 remove the exterior covers with unit power applied.

 

DO NOT

 remove the ultraviolet lamp (if installed) with unit power applied.

 

DO NOT

 look directly at the ultraviolet lamp (if installed) with unit power applied.

 

DO  NOT

 operate any appliance with a damaged or frayed power cord.   To disconnect the power

cord, grip the plug and pull it from the wall outlet, 

NEVER PULL ON CORD!

.

 

DO NOT

 use this appliance outdoors.   This appliance is intended for commercial, industrial,

institutional, and professional use.   Use of this product in a manner other than recommended

herein, may void the warranty.

 

DO  NOT

 operate this appliance without it being connected to an adequate water supply and purged of

air or damage to the pump may occur.

 

DO  NOT

 allow the cord to hang over the edge of a counter top or to touch hot surfaces.   NOTE:   If

an extension cord is used, verify that the rating of the extension cord is equal to or greater than

the  rating  of  the  appliance.

  Refer servicing of a defective or damaged unit to the factory or an authorized dealer.

  The use of attachments not recommended by the manufacturer may adversely affect the water

purity or cause appliance damage and void its warranty.

  Avoid contacting the dispensing outlets with any foreign materials or hands to prevent

contaminating  them.

Содержание HIGH PURITY WATER SYSTEM

Страница 1: ...ARIES HIGH PURITY WATER SYSTEM Operation Maintenance Manual Version 1 1a...

Страница 2: ...u have any questions concerning the operation of the unit or need service refer to section 11 0 REQUESTING SERVICE When requesting service you will need the model and serial number as well as the purc...

Страница 3: ...Principles of Purifying Water 4 0 Product Specifications 5 0 Before Using Your Dispenser 5 1 Setup 5 2 Installing the Cartridges 5 3 Startup Procedure 5 4 Initial Polishing of new cartridges 6 0 Displ...

Страница 4: ...er cord grip the plug and pull it from the wall outlet NEVER PULL ON CORD DO NOT use this appliance outdoors This appliance is intended for commercial industrial institutional and professional use Use...

Страница 5: ...ure successful water system operation Trace organic chemicals can interfere with highly sensitive reactions and alter biological processes TDS Total Dissolved Solids conduct electricity This conductiv...

Страница 6: ...t a glance The quick connect cartridge system makes replacing filters a simple task For optimum performance the Aries High Purity Water System may require reverse osmosis distillation or deionizing pr...

Страница 7: ...sformer UV Combination for Bacteria and TOC Wall Mounting Kit Reverse Osmosis Pre treatment Packages Re circulating Spray Gun 0 05 micron Pyrogen removal filter Typical Applications Media Prep Tissue...

Страница 8: ...tion valve at this time 5 2 Installing the Cartridges There are three 3 cartridge positions The water flows from left to right Any pretreatment filters must be installed in position 1 furthest from th...

Страница 9: ...g to confirm the effectiveness of the treatment process is the owners responsibility 6 0 DISPLAY AND KEYPAD FUNCTIONS Be sure you understand the function of each button before using them Function Keys...

Страница 10: ...e top cover by removing the phillips head screws that attach it Gently lift the top cover up and left and set it aside Unclasp the clamps that hold the stainless steel body of the UV light Gently lift...

Страница 11: ...rom the outlet Place a wad of paper towels around each plunger to absorb the small amount water that will come out of the filters plungers and or upper fitting Remove the three cartridges starting wit...

Страница 12: ...s 1 5 0 micron prefilter 1 GAC carbon filter and 1 1 0 micron post filter 9 5 Aries HPL RO Replacement Membrane AM 12 7010 Replacement membrane is a thin film composite PA membrane with 100 GPD output...

Страница 13: ...se barb connection 9 12 Blank Sanitization Cartridges VP 17 0000 Blank VP Style cartridges for sanitization of unit 3 required per Aries System Sanitization kit sold separately 10 0 REQUESTING SERVICE...

Страница 14: ...turned on Bad Solenoid Have unit serviced by an authorized dealer or return to factory A filter cartridge is loaded with particles and plugged No flow Replace the filter cartridge Capsule filter is bo...

Страница 15: ...llege of American Pathologists ASTM American Society for Testing and Materials NCCLS National Committee for Clinical Laboratory Standards EU Endotoxin Units N L No Limit The measurements of pH in Type...

Страница 16: ...anty ARIES ResinTech Inc assumes no other responsibility or liability This warranty does not cover any product which has been subject to misuse neglect accident or used in violation of operating instr...

Отзывы: