18 IPTV tests
ARGUS 165
199
Audio bytes
Sets the target value for audio bytes. When the measurement falls
below this threshold during the IPTV test, the display shows the test
result "FAIL", otherwise "OK".
Range: 0 to 6,553,600
Default:
0
Video bytes
Sets the target value for video bytes. When the measurement falls
below this threshold during the IPTV test, the display shows the test
result "FAIL", otherwise "OK".
Range: 0 to 6,553,600
Default:
0
RTP jitter
Establishes the limit values for RTP jitter.
Range: 0 to 2000 ms
Default:
100 ms
RTP sequence
errors
Establishes the limit values for sequence errors.
Range: 0 to 10,000
Default:
0
Current RTP
loss rate
Establishes the limit values for the current RTP loss rate.
Range: 0.00 % to 100.00 %
Default:
0.00 %
Total RTP
loss rate
Sets the limit values for the RTP loss rate for the entire test.
Range: 0.00 % to 100.00 %
Default:
5.00 %
Profile name
Enters a name for the IPTV profile.