Auto mode

: When the humidity in the room is 3% higher than the set one, the ventilation and the compressor start to 

work after 3 minutes. On the other hand, when the humidity in the room is 3% lower than the set one, the compressor 
stops while the ventilation continues for a short period of time. 
In Auto mode it is possible to adjust the ventilation and humidity level. 
 

Continuous mode

: The unit works continuously, but it is not possible to adjust the humidity level and ventilation. 

 

Sleep mode

: Press the Mode button on the control panel to activate this function, the symbol lights up on the display. If 

no selections are made on the control panel within 10 seconds, the display turns off and the fan speed changes from 
high to low. To reactivate the lighting, press any button on the control panel. Press the Mode button again to deactivate 
this function. 
In sleep mode, the fan speed cannot be adjusted but the humidity level can be adjusted. 
 

3. HUM BUTTON (HUMIDITY): 

press this button to adjust the desired humidity in the room (from 30 to 80%) in steps of 

5% By keeping this button pressed for a long time, the humidity level in the room is shown on the display. 

 

4. TIMER BUTTON

: allows you to program switching on (if the unit is off) or switching off (if the unit is on) from 0 to 24 

hours. Each time the button is pressed, the adjustment interval corresponds to 1 hour, and it is possible to view the time 

set on the display, the symbol on the display remains lit during the set time interval. It is always possible to view the set 

time by pressing the Timer button, then the display will return to showing the humidity level detected in the environment. 

To deactivate the Timer, “00” must appear on the display (flashes 4 times), and the Timer symbol on the display will turn 

off. 

 

5. SPEED BUTTON (VENTILATION SPEED)

: It is possible to adjust the ventilation speed only in Auto mode. Press this 

button to adjust the speed from high to low, the corresponding symbols will light up on the display according to the 

selection made. 

 

6. LOCK BUTTON

: Long press of this button activates the control panel lock function, the corresponding symbol on the 

display lights up, and it is no longer possible to make selections on the control panel. Long press this button again to 

deactivate this function, the symbol goes off on the display. 

When the appliance is switched off, the child lock function is automatically deactivated. 
 

MEMORY FUNCTION: 

the dehumidifier starts up again after a power failure keeping last settings. 

 

COLOR LED  

 
On the front panel of the dehumidifier there is a LED that shows different colors based on the humidity level detected in the 
room: 
 
Blue = Ambient humidity below 45% 
Green = Ambient humidity between 45% and 65% 
Red = Ambient humidity above 65% 
If E0, E2, CL, CH, LO, HI appear on the display on the control panel, the color of the LED will be red. 
(for error codes refer to the troubleshooting section). 
 
 

CLEANING AND MAINTENANCE 

 

MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE 

 

 

Warning 

Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric 
shock and malfunction.  
 

 

Warning 

Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.  
 
Use a damp and soft cloth to clean the exterior surface of the dehumidifier. 
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage 
the surface or colour of the casing. 

 
 
 

 

 
 

Содержание LILIUM ART 11

Страница 1: ...UCTIONS Read the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ...n different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that doesn t have any continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not p...

Страница 3: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure the plug is inserted fully Do not use multiple adapters Do not touch the plug with wet hands Make sure the plug is clean Children aged be...

Страница 4: ...s water leaks can cause it to malfunction or cause excessive vibration and running noise The dehumidifier must be positioned at least 50 cm away from the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles i...

Страница 5: ...ng so can cause leaks and malfunction In the event of interference with other electrical appliances place the two products at a minimum distance of 70cm DESCRIPTION OF PARTS 1 Control panel 8 Side panel 2 Colored LED with humidity sensor 9 Air inlet and air filter 3 Front panel 10 Water tank 4 Casters 11 Water outlet 5 Side panel 12 Air outlet 6 Handle 13 Power cord 7 Rear panel FRONT VIEW REAR VI...

Страница 6: ...t is in operation If you wish to make continuous draining of condensate follow the instructions in the dedicated paragraph OPERATING PRECAUTIONS The dehumidifier starts only if the humidity level in the room is higher than 3 the set one The dehumidifier will continue to operate until the set humidity level is reached except for any interruptions due to filling the tank When the water tank is full ...

Страница 7: ...ich is inside the tank is correctly positioned Make sure not to damage the float and the locking rivet which are inside the tank otherwise the unit will not automatically stop working when the water tank is full and the water could leak out and risk wetting the tank floor and damage the appliance N B Do not use the drainage pipe when you want to collect the condensate in the tank otherwise the wat...

Страница 8: ...lay then set the desired humidity level During operation the Power symbol on the display remains always on and the display shows the humidity level detected in the room during operation of the dehumidifier By pressing this button again the unit stops working and the ventilation stops 2 MODE BUTTON The unit works in the following circular sequence Auto Mode Continuous Mode Sleep Mode the correspond...

Страница 9: ...howing the humidity level detected in the environment To deactivate the Timer 00 must appear on the display flashes 4 times and the Timer symbol on the display will turn off 5 SPEED BUTTON VENTILATION SPEED It is possible to adjust the ventilation speed only in Auto mode Press this button to adjust the speed from high to low the corresponding symbols will light up on the display according to the s...

Страница 10: ...ly then insert it back into its housing Do not use hair dryer or fire to dry the filter Do not use sponges or brushes to clean the filter as they can damage it 2 2 Reposition the filter by inserting it as indicated by the arrow and replace the water tank Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator resulting in higher energy consumption CONSERV...

Страница 11: ...d and the dehumidifier stops REGULATION EU N 517 2014 F GAS LILIUM ART 11 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 045 0 000135 Tons CO2 equiv Do not release R290 into the atmosphere LILIUM ART 13 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 050 0 000150 Tons CO2 equiv Do not release R290 into the atmospher...

Страница 12: ...se any sources of ignition in such a manner that it may lead to the risk of fire or explosion AII possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed...

Страница 13: ...ceptable for all refrigerant systems Electronic leak detectors may be used to detect refrigerant leaks but in the case of flammable refrigerants the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipm...

Страница 14: ...ed refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed For appliances containing flammable refrigerants ensure that there are labels on the equipment stating the equipment contains flammable refrigerant R...

Отзывы: