The following space must be maintained to ensure the operating efficiency of the dehumidifier.  
 

 

 

 

OPERATING INSTRUCTIONS 

 

APPLIANCE START-UP 

 
Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive 
materials and 50 cm away from walls or other obstructions. 
Make sure the water tank is in the correct position.  
Connect the power cord to a suitable electric socket (220-240V

/1/50Hz). 

Turn the appliance on with POWER on the control panel.

 

The unit emits a sound signal and is in standby, the colored 

LED on the front panel lights up. The display shows the humidity% detected in the room, therefore set a humidity % 
lower than at least 3% compared to that in the room to make the dehumidifier work. 
The dehumidifier is designed to operate at ambient temperatures from 

+ 5°C to + 35°C

If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.  
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running. 
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification 
function may intermit: please don’t turn off the switch or pull out the power plug of the dehumidifier.  

We recommend not using the dehumidifier in room temperatures lower than 5°C. 

Do not remove the tank when the unit is in operation. 
If you wish to make continuous draining of condensate, follow the instructions in the dedicated paragraph. 

 

OPERATING PRECAUTIONS

 

The dehumidifier starts only if the humidity level in the room is higher than 3% the set one. 

The dehumidifier will continue to operate until the set humidity level is reached, except for any interruptions due 
to filling the tank. 

When the water tank is full, the compressor stops running immediately and dehumidification stops; the fan stops after 3 
minutes. Empty the tank and reposition it: after carrying out these operations, the unit will start operating again. 

 
ATTENTION: 
After each interruption of operation, at least 3 minutes must elapse before the dehumidifier restarts: this start-
up delay protects the compressor from damage. 

If, on the other hand, the humidity% set is higher than that present in the room, the dehumidifier will not start. 
If, after following the instructions for starting the dehumidifier, the dehumidifier does not start and the (POWER) symbol 
does not light up, or the dehumidifier stops without reason, check that the condition of the plug and the power cord are 
good. Once this is done, wait 10 minutes and then restart the dehumidifier. 
If, even after 10 minutes, the dehumidifier does not start, or if the cable or the plug are damaged, switch off the 
dehumidifier and contact a technical assistance center. 

 
WARNING: 
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the 
room. The room temperature will therefore tend to increase. This is completely normal. 
 
 

50 cm 

50 cm 

Содержание LILIUM ART 11

Страница 1: ...UCTIONS Read the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ...n different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that doesn t have any continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not p...

Страница 3: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure the plug is inserted fully Do not use multiple adapters Do not touch the plug with wet hands Make sure the plug is clean Children aged be...

Страница 4: ...s water leaks can cause it to malfunction or cause excessive vibration and running noise The dehumidifier must be positioned at least 50 cm away from the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles i...

Страница 5: ...ng so can cause leaks and malfunction In the event of interference with other electrical appliances place the two products at a minimum distance of 70cm DESCRIPTION OF PARTS 1 Control panel 8 Side panel 2 Colored LED with humidity sensor 9 Air inlet and air filter 3 Front panel 10 Water tank 4 Casters 11 Water outlet 5 Side panel 12 Air outlet 6 Handle 13 Power cord 7 Rear panel FRONT VIEW REAR VI...

Страница 6: ...t is in operation If you wish to make continuous draining of condensate follow the instructions in the dedicated paragraph OPERATING PRECAUTIONS The dehumidifier starts only if the humidity level in the room is higher than 3 the set one The dehumidifier will continue to operate until the set humidity level is reached except for any interruptions due to filling the tank When the water tank is full ...

Страница 7: ...ich is inside the tank is correctly positioned Make sure not to damage the float and the locking rivet which are inside the tank otherwise the unit will not automatically stop working when the water tank is full and the water could leak out and risk wetting the tank floor and damage the appliance N B Do not use the drainage pipe when you want to collect the condensate in the tank otherwise the wat...

Страница 8: ...lay then set the desired humidity level During operation the Power symbol on the display remains always on and the display shows the humidity level detected in the room during operation of the dehumidifier By pressing this button again the unit stops working and the ventilation stops 2 MODE BUTTON The unit works in the following circular sequence Auto Mode Continuous Mode Sleep Mode the correspond...

Страница 9: ...howing the humidity level detected in the environment To deactivate the Timer 00 must appear on the display flashes 4 times and the Timer symbol on the display will turn off 5 SPEED BUTTON VENTILATION SPEED It is possible to adjust the ventilation speed only in Auto mode Press this button to adjust the speed from high to low the corresponding symbols will light up on the display according to the s...

Страница 10: ...ly then insert it back into its housing Do not use hair dryer or fire to dry the filter Do not use sponges or brushes to clean the filter as they can damage it 2 2 Reposition the filter by inserting it as indicated by the arrow and replace the water tank Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator resulting in higher energy consumption CONSERV...

Страница 11: ...d and the dehumidifier stops REGULATION EU N 517 2014 F GAS LILIUM ART 11 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 045 0 000135 Tons CO2 equiv Do not release R290 into the atmosphere LILIUM ART 13 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 050 0 000150 Tons CO2 equiv Do not release R290 into the atmospher...

Страница 12: ...se any sources of ignition in such a manner that it may lead to the risk of fire or explosion AII possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed...

Страница 13: ...ceptable for all refrigerant systems Electronic leak detectors may be used to detect refrigerant leaks but in the case of flammable refrigerants the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipm...

Страница 14: ...ed refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed For appliances containing flammable refrigerants ensure that there are labels on the equipment stating the equipment contains flammable refrigerant R...

Отзывы: