TURNING THE DEHUMIDIFIER OFF

 

To turn the dehumidifier off press the POWER button. This shuts off power to the unit. 
Unplug the appliance if you do not intend to use it for some time. 
 

HOW TO ELIMINATE CONDENSATE

 

The water extracted from the air can be collected in the provided front tank. 
When the tank is full, not inserted or not correctly inserted, the FULL TANK led turns on and the unit beeps for about 10 
seconds, at the end of which the unit turns off.   
To switch off the appliance, press the POWER button and wait a few seconds. 

1. Carefully pull out the tank, following the direction of the arrow. 
2. Empty the tank and dry it thoroughly. 
3. Reposition the tank 
4. Press the POWER button again to turn on the unit. 

NB: If the full tank LED remains lit even after emptying the tank, check that the float, which is inside the tank, is correctly 
positioned. 

  

 

Make sure not to damage the float and the locking rivet, which are inside the tank, otherwise the unit will not 
automatically stop working when the water tank is full, and the water could leak out and risk wetting the tank. floor and 
damage the appliance. 
N.B. Do not use the drainage pipe when you want to collect the condensate in the tank, otherwise the water could come 
out from the pipe. 
 

CONTINUOUS CONDENSATE DRAINAGE

 

The water can be continuously drained when using a PVC hose with an inner diameter of 11 mm (supplied). 
Turn off the appliance and remove the plug before connecting the hose. 
Connect the tube to the condensate drain hole securely and prepare a container that can hold the water. The tube must 
be connected without bends or bends, to facilitate an easy drainage of the condensate, and must be positioned at a 
greater height than the drain hole. 
When disconnecting the hose, prepare a container to collect any residual water that may leak out of the hose. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание LILIUM ART 11

Страница 1: ...UCTIONS Read the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these instructions in a safe place for future reference EN ...

Страница 2: ...n different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that doesn t have any continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not p...

Страница 3: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure the plug is inserted fully Do not use multiple adapters Do not touch the plug with wet hands Make sure the plug is clean Children aged be...

Страница 4: ...s water leaks can cause it to malfunction or cause excessive vibration and running noise The dehumidifier must be positioned at least 50 cm away from the wall or other obstacles so that the heat can dissipate correctly Close all open windows to maximise dehumidification efficiency Do not insert objects or sharp instruments into the air outlet grille Do not cover the air intake and outlet grilles i...

Страница 5: ...ng so can cause leaks and malfunction In the event of interference with other electrical appliances place the two products at a minimum distance of 70cm DESCRIPTION OF PARTS 1 Control panel 8 Side panel 2 Colored LED with humidity sensor 9 Air inlet and air filter 3 Front panel 10 Water tank 4 Casters 11 Water outlet 5 Side panel 12 Air outlet 6 Handle 13 Power cord 7 Rear panel FRONT VIEW REAR VI...

Страница 6: ...t is in operation If you wish to make continuous draining of condensate follow the instructions in the dedicated paragraph OPERATING PRECAUTIONS The dehumidifier starts only if the humidity level in the room is higher than 3 the set one The dehumidifier will continue to operate until the set humidity level is reached except for any interruptions due to filling the tank When the water tank is full ...

Страница 7: ...ich is inside the tank is correctly positioned Make sure not to damage the float and the locking rivet which are inside the tank otherwise the unit will not automatically stop working when the water tank is full and the water could leak out and risk wetting the tank floor and damage the appliance N B Do not use the drainage pipe when you want to collect the condensate in the tank otherwise the wat...

Страница 8: ...lay then set the desired humidity level During operation the Power symbol on the display remains always on and the display shows the humidity level detected in the room during operation of the dehumidifier By pressing this button again the unit stops working and the ventilation stops 2 MODE BUTTON The unit works in the following circular sequence Auto Mode Continuous Mode Sleep Mode the correspond...

Страница 9: ...howing the humidity level detected in the environment To deactivate the Timer 00 must appear on the display flashes 4 times and the Timer symbol on the display will turn off 5 SPEED BUTTON VENTILATION SPEED It is possible to adjust the ventilation speed only in Auto mode Press this button to adjust the speed from high to low the corresponding symbols will light up on the display according to the s...

Страница 10: ...ly then insert it back into its housing Do not use hair dryer or fire to dry the filter Do not use sponges or brushes to clean the filter as they can damage it 2 2 Reposition the filter by inserting it as indicated by the arrow and replace the water tank Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator resulting in higher energy consumption CONSERV...

Страница 11: ...d and the dehumidifier stops REGULATION EU N 517 2014 F GAS LILIUM ART 11 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 045 0 000135 Tons CO2 equiv Do not release R290 into the atmosphere LILIUM ART 13 The unit contains R290 a natural greenhouse gas with global warming potential GWP 3 Kg 0 050 0 000150 Tons CO2 equiv Do not release R290 into the atmospher...

Страница 12: ...se any sources of ignition in such a manner that it may lead to the risk of fire or explosion AII possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which refrigerant can possibly be released to the surrounding space Prior to work taking place the area around the equipment is to be surveyed...

Страница 13: ...ceptable for all refrigerant systems Electronic leak detectors may be used to detect refrigerant leaks but in the case of flammable refrigerants the sensitivity may not be adequate or may need re calibration Detection equipment shall be calibrated in a refrigerant free area Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used Leak detection equipm...

Страница 14: ...ed refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked Labelling Equipment shall be labelled stating that it has been de commissioned and emptied of refrigerant The label shall be dated and signed For appliances containing flammable refrigerants ensure that there are labels on the equipment stating the equipment contains flammable refrigerant R...

Отзывы: