![Argo AUR210CL Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/argo/aur210cl-series/aur210cl-series_technical-data-and-service-manual_2967482006.webp)
6
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
Number ... Dia.
(mm)
1.... ø 320
1.... ø 380
1.... ø 380
No. of pole .... rpm (220V, high)
6 ....... 860
6 ....... 860
6 ....... 860
Nominal output
W
58
70
70
Coil resistance
Ω
BLU - BRN: 249 ÷ 287
BLU - BRN: 218 ÷ 251
BLU - BRN: 218 ÷ 215
(Ambient temp. 25 °C)
BLU - BLK : 270 ÷ 311
BLU - BLK: 230 ÷ 265
BLU - BLK: 230 ÷ 265
Coil
Aluminum plate fin / Copper tube
Rows 2
2
2
Fin pitch
mm
1,6
1,6
1,6
Face area
m
2
0,255 0,3 0,3
SAFETY DEVICES
Internal type
THERMOSTAT (DEFROST THERMO.)
HEAT EXCH. COIL
Temperature
Temperature air °C intake temp. Temperature air °C intake temp.
Maximum 32 °C DB / 22 °C WB 46 °C DB
Minimum
19 °C DB / 14 °C WB
19 °C DB
Maximum
27 °C DB / 19 °C WB
24 °C DB / 18 °C WB
Minimum
- DB / - WB
-8 °C DB / -9 °C WB
Open °C
150
±
10%
Close °C
Automatic reclosing
µF 2
2,5
2,5
VAC 450
450
450
Operating temp.
Run capacitor
MODEL
AUR210CLXXX AUR213CLXXX AUR310HLXXX
Temperature
Temperature air °C
Temperature air °C
intake temp.
intake temp.
Maximum
32 °C DB / 23 °C WB
46 °C DB
Minimum
19 °C DB / 14 °C WB
19 °C DB
B
OPERATING RANGE COOLING MODELS
OPERATING RANGE HEAT PUMP MODELS
FAN & FAN MOTOR
Proppeler Proppeler Proppeler
Operating temp.
—
—
ON - Close 12 ± 2 Diff. + 0/8 °C
Contact rating
—
—
AC 120 V 0,5A
b) OUTDOOR UNIT (LITTLE BAG)
Cooling
Cooling
Heating