Argo AUR210CL Series Скачать руководство пользователя страница 3

3

Controls / temperature control 

Microprocessor / I.C. Thermostat

Control unit 

Wireless remote control unit

Timer 

ON / OFF 24 hours and program

Fan speed indoor / outdoor 

3 and auto / 1

Horizontal Manual

Vertical Manual

Air filter 

Washable, easy access

Compressor Rotary 

(hermetic)

Refrig./Stand. charge at shipment      

910 

1220 

1030

Tot. refrig. charge with 2 m extension 

960 

1270 

1090

Tot. refrig. charge with 4 m extension 

1010 

1320 

1150

Refrigerant control 

Capillary tube

Idoor Hi/Me/Lo dB-A 

44 / 40 / 39 

46 / 42 / 41 

44 / 40 / 39

Outdoor Hi dB-A 

54 

51 

51

Stand. tubing length 

~ 2,5

Tubing length with 2 m extension kit 

~ 4,5

Tubing length with 4 m extension kit 

~ 6,5

DIMENSIONS AND WEIGTH 

UNIT DIMENSIONS

Indoor unit 

Height 

mm 

790

Width mm 

580

Depth mm 

245

Outdoor unit 

Height 

mm 

435 

490 

490

Width mm 

440  525 

525

Depth mm 

230  250 

250

Net weight / indoor unit - outdoor unit 

kg 

44 / 9,5 

44 / 15 

44 / 15

PERFORMANCES COOLING 

COOLING 

HEATING

Voltage rating 

220 

÷

240 

Available voltage range 

198 

÷

264 

Running ampere A 4,4  6.2 4.2 4.3

Power input W 980                       1300 940                         950

Power factor % 0,96 0,91 0,97  0,96

C.O.P. W/W   

2.70 

2.82 

2.98 

3,31

Compressor locked rotor amperes A 23 34 23

Power source 

220 - 240 ~ 50Hz

BTU / h 

9500 

12500 

9820 

10700

W (Kcal / h) 2650 (2270) 3670 (3150) 2800 (2400) 3140 (2700)

Air circulation (high/med/low) m

/ h 370/340/270 450/400/340 370/340/270

Moisture removal (high speed) l / h 1,2 1,5 1,2

UNIT MODEL

Capacity

Airflow direction
(Indoor)

Livello rumore

AUR210CLXXX        AUR213CLXXX 

AUR310HLXXX

1) UNIT SPECIFICATIONS

NOTA

Rating conditions:

Cooling: 

outside air temp.: 35°C DB, indoor unit entering air temp.: 27 °C DB, 19 °C WB

Heating: 

outside air temp.: 7°C DB, 6 °C WB, indoor unit entering air temp.: 20 °C DB

Data subject to change without notice.

A

SPECIFICATIONS

FEATURES

ELECTRICAL RATINGS

Содержание AUR210CL Series

Страница 1: ...TECHNICAL DATA SERVICE MANUAL ROOM AIR CONDITIONER WITH REMOTE CONDENSER TEST OFF ON AUR210CLXXXX AU213CLXXXX AUR310HLXXX COOLING ONLY VERSION R407C HEAT PUMP VERSION R407C 0 8180 090 1 05 2000...

Страница 2: ...aker trips or fuse blows Circuit breaker trips in several minutes after turning air conditioner ON Water level alarm lamp is flashing Outdoor unit and compressor do not run Some part of air conditione...

Страница 3: ...Width mm 440 525 525 Depth mm 230 250 250 Net weight indoor unit outdoor unit kg 44 9 5 44 15 44 15 PERFORMANCES COOLING COOLING HEATING Voltage rating V 220 240 Available voltage range V 198 264 Run...

Страница 4: ...C 3 0 5 10 C 9 9 5 50 C 2 1 5 Resistance k 10 C 10 0 4 30 C 4 0 4 15 C 7 9 4 35 C 3 3 4 20 C 6 3 4 40 C 2 7 4 25 C 5 0 4 50 C 1 8 4 COMPRESSOR Rotary hermetic Controls Microprocessor Control circuit f...

Страница 5: ...pen C 115 4 Close C 95 10 MODEL AUR210CLXXX AUR213CLXXX AUR310HLXXX Overload relay OLR External type Operating temp Open C 140 5 135 7 140 5 Close C 69 11 69 11 69 11 F 56 VAC 330 Run capacitor C4 Rat...

Страница 6: ...intake temp Temperature air C intake temp Maximum 32 C DB 22 C WB 46 C DB Minimum 19 C DB 14 C WB 19 C DB Maximum 27 C DB 19 C WB 24 C DB 18 C WB Minimum DB WB 8 C DB 9 C WB Open C 150 10 Close C Aut...

Страница 7: ...7 C DIMENSIONAL DATA Indoor unit Outdoor unit 580 835 245 230 440 425 DIMENSIONS mm HEAT PUMP MODEL AND AUR213CLXXX 790 580 440 490 230 250 435 490 245...

Страница 8: ...25 30 35 40 45 OUTDOOR INLET AIR D B TEMP C AUR213CLXXX AUR210CLXXX 32 27 19 Operating characteristics versus outdoor ambient temperature and indoor temperature Conditions Power source 230 V 1 50Hz Si...

Страница 9: ...G CURRENT A OUTDOOR INLET AIR D B TEMP C INDOOR INLET AIR D B TEMP C 20 25 30 35 40 45 Operating characteristics versus outdoor ambient temperature and indoor temperature Conditions Power source 230 V...

Страница 10: ...cal filter Heat exchanger Heat exchanger Outdoor unit Indoor unit REFIGERANT FLOW DIAGRAM HEAT PUMP MODELS Heat exchanger Muffler Stainer 4 way valve Accumulator Compressor Heat exchanger Drier Capill...

Страница 11: ...rmo OFF When the room temperature in equal to or below set temperature T C Compressor OFF F FUNCTION 1 ROOM TEMPERATURE CONTROL Cooling Room temperature control is obtained by cycling the compressor O...

Страница 12: ...emperature T C Compressor OFF Heating Room temperature control is obtained by cycling the compressor ON and OFF under control of the room temperature sensor in the remote control unit The room tempera...

Страница 13: ...ORE THAN 6 MINUTES INDOOR FAN COMPRESSOR INDOOR HEAT EXCH COIL TEMP T 1 C T C SET TEMP 1 C 3 OVERLOAD PREVENTION HEATING This function prevents overheating for the indoor heat exchange coil COMPRESSOR...

Страница 14: ...D HEATING HEAT PUMP MODEL When auto mode is selected the microprocessor calculates the difference between the set temperature and the room temperature and automatically switches to cooling or heating...

Страница 15: ...for at least 6 minutes Outdoor fan is either operated or stopped for more than 10 minutes Is outdoor fan continuolsy opera ting for more than 10 minutes Integrate operating time of com pressor is more...

Страница 16: ...N ON OFF OFF OFF OFF OFF OFF OFF ON ON ON 32 SEC MAX 12 MIN 32 SEC 2 SEC START OF DEFROSTING RELEASE OF DEFROSTING RELEASE OF COLD DRAFT PREVENTION INDOOR HEAT EXCH COIL TEMP 35 C STANDBY LAMP COMPRES...

Страница 17: ...RSION SCHEMA ELETTRICO VERSIONE SOLO RAFFREDDAMENTO SCH MA LECTRIQUE VERSION FROID SEUL SCHALTPLAN AUSF HRUNG NUR K LUNG ESQUEMA ELECTRICO SCHALTPLAN MODELOS QUE SOLO EINFRIAN HLEKTRIKODIAGRAMMA EKDOS...

Страница 18: ...EAT PUMP VERSION SCHEMA ELETTRICO VERSIONE POMPA DI CALORE SCH MA LECTRIQUE VERSION POMPE CHALEUR SCHALTPLAN W RMEPUMPE AUSF HRUNG ESQUEMAELECTRICO SCHALTPLAN MODELOS BOMBADE CALOR HLEKTRIKODIAGRAMMA...

Страница 19: ...insu lation is defective B There is a possibility of short circuit Circuit breacker trips in several minutes after turning air conditioner ON NO NO YES YES Check capacity of circuit breaker Capacity o...

Страница 20: ...pump PC without it Connect the first white wire to N terminal of unit terminal strip The connetc the second white wire to the power relay PR NO ter mial for AU 310 HL unit 8 termial for AU 213 CL uni...

Страница 21: ...tor DEFECTIVE DEFECTIVE OK Check fan motor capacitor Replace Measure resistance of fan motor winding Replace fan motor Fan cannot be turned Check fan rotation Turn fan gently once or twice by hand Rem...

Страница 22: ...control unit AIR CONDITIONER OPERATES BUT ABNORMALITIES ARE OBSERVED HEAT PUMP MODEL 1 Operation does not switch from heat to cool or cool to heat Remote control unit may be defective Measure resistan...

Страница 23: ...ck selector B on back of remote control to see which is selected A C or RCU First remote control unit is defective Room sensor in remote control unit is defec tive That is sensor is SHORT First remote...

Страница 24: ...LOW Measure temperatures of suction and discharge air of air conditioner Review cooling or heating load esti mate if performance of air conditio ner is normal Air filter is clogged Change position of...

Страница 25: ...ventilation Fault with serial communication between the two controllers PCB1 PCB2 ground fault on connecting wires When the air conditioner is submit to an high magnetic noise electronic locking of m...

Страница 26: ...plunger welded to the service connection quick connection to the pump pipes Reload of the system after a maintenance intervention or after an uncorrect detach of the connection pipe Before disconnecti...

Страница 27: ...sealing of the aeroquip quick connections The full charge of refrigerant must be restored to the indoor unit Outdoor unit little bag bleeding Connect the vacuum pump already equipped with service conn...

Страница 28: ...d measure the resistance by placing a probe on N terminal and then on L terminal the terminal plate Fig 2 b Measurement of Insulation Resistance for Electrical Parts Disconnect the lead wires of the d...

Страница 29: ...citor is good if the pointer bounces to a great extent and the gradually returns to its origi nal position The range of deflection and deflection time deffer according to capacity of the capacitor Fig...

Отзывы: