4
SAFETY DEVICES
FAN & FAN MOTOR
CONTROLLER P.C.B.
MODEL
AUR210CLXXX AUR213CLXXX AUR310HLXXX
Primary
AC 235 V - 50 Hz
AC 235 V - 50 Hz
AC 235 V - 50 Hz
Secondary
11 V - 0,727 A
11 V - 0,727 A
19 V - 0,526 A
Capacity
8 VA
8 VA
10 VA
Coil resistance (at 22 °C) Primary
Ω
WHT - WHT: 214
±
10%
WHT - WHT: 214
±
10% WHT - WHT: 205
±
10%
Secondary
BRN - BRN: 1,58
±
20%
BRN - BRN: 1,58
±
20% BRN - BRN: 2,0
±
10%
Thermal cutoff temp.
145 °C - 2A
145 °C - 2A
145 °C - 2A
150 °C
Coil rated
AC 230 V
AC 220 V
AC 24 V
Coil resistance (at 20 °C)
K
Ω
7.250
±
10% 21
±
15% 650
±
10%
Contact rated
AC 250 V - 30A
AC 220 V - 25A
AC 25 V - 20A - L.R.A. 60A
Resistance k
Ω
-20 °C 40,1
±
5%
20 °C 6,5
±
5%
-10 °C 24,4
±
5%
30 °C 4,4
±
5%
0 °C 15,3
±
5%
40 °C 3,0
±
5%
10 °C 9,9
±
5%
50 °C 2,1
±
5%
Resistance k
Ω
10 °C 10,0
±
4%
30 °C 4,0
±
4%
15 °C 7,9
±
4%
35 °C 3,3
±
4%
20 °C 6,3
±
4%
40 °C 2,7
±
4%
25 °C 5,0
±
4%
50 °C 1,8
±
4%
COMPRESSOR....
(Rotary hermetic)
Controls Microprocessor
Control circuit fuse
250V - 3A
Cross - flow
Number ... dia. / Lenght
mm
1 ... ø 100 / L 410
Nominal output
W
27
Coil resistance
Ω
GRY - WHT: 545 ÷ 630
(Ambient temp. 25 °C)
WHT - VLT: 92 ÷ 105
VLT - YEL: 62 ÷ 71
YEL - BRN: 780 ÷ 900
Internal thermo fuse
Open °C
150
±
10
Close °C
Automatic
reclosing
µF 1,0
1,5
1,0
VAC 440
440
440
THERMISTOR (COIL SENSOR) TH1
TRANSFORMER
POWER RELAY (COMPRESSOR)
Nominal outpot W 950 1290 950
Compressor oil
cc
500 550 500
Coil resistance
Ω
C - R: 3,01
±
7% C - R: 1.92
±
7% C - R: 3,01
±
7%
(Ambient temp. 20 °C) C - S: 7,82
±
7% C - S: 5.29
±
7% C - S: 7,82
±
7%
Rated
2) MAJOR COMPONENT SPECIFICATIONS
a) INDOOR UNIT
Operating
temp.
Run capacitor
THERMISTOR (ROOM SENSOR) TH2
80228245B
80228245B
80235245B