Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 25
www.argo-hytos.com
10.6
Replacing the particle monitor OPCom
DANGER
Danger to life
Risk of electric shock
›
Before uninstalling, pull the mains plug. Uninstalling may only be carried out by qualified electricians.
Risk of injury
Risk of injury by incorrect handling
›
Uninstalling may only be carried out by instructed persons.
CAUTION
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded during
operation.
›
Allow the filter unit to cool down before touching it.
6. Screw the assembly with the nuts (Pos. 8) (tightening torque 15+2 Nm).
The device can be put into operation.
If not oil is sucked during commissioning, open the cover at the filter housing and fill in about 300 ml oil.
10.6.1 Removing the OPCom
1. Unplug the power cord from the bottom of the OPCom (cable not shown).
2. Loosen the angle screw connection at the inlet (1) and outlet (2).
3. Loosen the hexagonal screws (4).
4. Raise the particle monitor (3).
DANGER
Danger to life
Risk of electric shock
›
Before uninstalling, pull the mains plug. Uninstalling may only be carried out by qualified electricians.
10.6.2 Installing the OPCom
The installation is carried out in reverse order as described above.
Fig. 13: Replacing the measuring sensor