6. Transport and storage
6.1 Transport
Fig.3: Transport by carrying
The compact design allows for easy transport of the FAPC 016 filter unit – even
to inaccessible parts of hydraulic systems.
Hoses and electrical cables can be attached to the device. The device can be
transported and operated both standing upright and lying flat.
Please note the instructions in Chapter 2 "Safety instructions".
›
When using mobile transport aids, ensure a secure position of the unit
(danger of tipping).
›
During transport, secure the suction hose and the pressure hose in the brackets
provided for this purpose in order to avoid a possible leakage of residual oil.
6.2 Storage
The filter unit FAPC 016 should be stored in an enclosed area to protect it from humidity and condensation.
DANGER
Risk of injury
Danger of chemical reactions
Chemical substances in the immediate vicinity of the filter unit can react and lead to the destruction of the device
and to injuries to persons in the immediate vicinity of the device.
›
Storage in the immediate vicinity of chemically active substances such as acids, alkalis, salts, organic solvents
and rechargeable batteries is prohibited.
The ambient temperature during storage of the filter unit FAPC 016 should be b5 °C und +50 °C at a maximum humidity
of 80 %.
Before storage over a period of more than 6 months, the device should be filled with oil in order to preserve it against corrosion.
CAUTION
Falling unit by incorrect transport
Injuries! Damage!
›
Due to its weight of 22 kg, the device must be carried manually by two persons.
›