BIOS CONFIGURATION
39
In a PC system with only one or two drives, the power can sup-
ply enough power to spin up both drives simultaneously. But In
a systems with more than two drives, the startup current from
spinning up the drives all at once can overload the power sup-
ply, causing damage to the power supply, disk drives and other
system components. This damage can be avoided by allowing
the host to stagger the spin-up of the drives. New SATA drives
have supported staggered spin-up capabilities to boost reli-
ability. Staggered spin-up is a very useful feature for managing
multiple disk drives in a storage subsystem. It gives the host
the ability to spin up the disk drives sequentially or in groups,
allowing the drives to come ready at the optimum time without
straining the system power supply. Staggering drive spin-up in a
multiple drive environment also avoids the extra cost of a power
supply designed to meet short-term startup power demand as
well as steady state conditions.
3.2.2.11.1 #Disks Per Spin-up Group
To define the # of disks per spin-up group, highlight the "#
Disks Per Spin-up Group" field from the "Staggered Spin-
up Config" screen and press
Enter
. A screen similar to the
following appears:
ARC-1330 series host adapters have included the option for
customer to select the number of disk drives group per stagger
power up value. The values can be selected fro
m 1 to 8 disks
per step which powers up the system.
Adapter#1- I/O=FD9FF000h, F2(Tab): Select Controller, F10: Reset System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Return To Previous Menu Item
Areca Technology Corporation SAS Controller
Main Menu
Physical Devices
Miscellaneous Settings
System Information
Miscellaneous Settings
Miscellaneous Settings
SATA NCQ Support
SMART Status Polling
Disk Write Cache
PCI Interrupt Type
PCIE Read Request Size
Max. Phy Link Rate
Max. Command Xfer Length
Delay Before Driver Load
INT 13 Service
Clear Persistent Mapping
Staggered Spin-up Config
Reset BIOS Parameters
Staggered Spin-up Config
Staggered Spin-up Config
Disk Per Spin-up Group
Group Spin-up Delay(Seconds)
#Disks Per Spin-up Group
#Disks Per Spin-up Group
1
2
3
4
5
6
7
8
8
Содержание ARC-1330 Series
Страница 5: ......