background image

Original User Manual 

 A

REBO

S SPA Pool  

 

12 

 
 

3.3 Installation of LED lights (where applicable) 

 

SPA pool type without LED lighting kit please direct to 3.4; 

 

 

The LED lighting kit is in delivery and suitable for type: 

CORFU   PALMA   TENERIFE   

SANTORIN    BALI   MONACO

 

 

Check the scope of delivery for remote control, power cable, connection cable and LED-roll.  

 

After the spa is completely inflated, turn it “upside down”. Unroll the LED

-strip completely. 

Pass it through the tabs at the bottom of the pool, starting at the control unit.  

 

 

 

 

The 

electrical connection

 is made by the power supply unit and connecting cable. Pay 

attention to the groove in the plug.  

 

 

Different colors, brightness and modes can be selected with the 

remote control

.  

 

CAUTION! Make sure Lighting is NOT tight between the loops.

 

They must be fitted loosely

, with excess LED to move between the retention loops on the base 

of the hot tub.  
This reduces stress on the strip and allows the lighting strip expand when filled with water. 

 

Middle:

 Receiver Remote 

control 

Left:

 black connection to 

power supply (2-pin plug) 

Right:

 transparent 

connection to the pool (4-
pin plug) 

Make sure that the LED-

lamps face the base of 

pool. 

 

Содержание AR-HE-SPA2OCLH

Страница 1: ...ual AREBOS SPA Pool 1 SPA Pool Style of the hot tub may differ from image shown above List of contents Please follow all security measures in this user s manual to ensure a secure use Thank you for tr...

Страница 2: ...Installation of LED lights where applicable 12 3 4 Fill the spa pool with water 13 3 5 Connect the spa to the mains 13 4 Operation 14 4 1 Before using the pool for the first time 14 4 2 Control panel...

Страница 3: ...s article Caution Make sure the product is grounded Warning of electrical voltage Note Pull out the mains plug Risk of drowning It is essential to ensure that children do not have access to the spa wi...

Страница 4: ...sk of injury 1 2 3 Electricity and electric shock hazard Warning Maintenance and repair work on the electrical components and any replacement of the power cable may only be carried out by a qualified...

Страница 5: ...1 2 4 Cartridge filter and suction power If the cartridge filter is missing or defective long hair or parts of the body can be sucked in and get into the supply line which can lead to serious acciden...

Страница 6: ...o recognize impending dangers lack of heat awareness lack of feeling for the heat when leaving the bubble bath inability to leave the bubble bath damage to the fetus in pregnant women loss of consciou...

Страница 7: ...ver the pool when it is not in use This can prevent children from using the pool unsupervised Caution The pool should not be operated at temperatures below 4 C Caution The continuous filter and heatin...

Страница 8: ...l h 1400 l h 1400 l h 1400 l h Temperature increasing rate 1 0 2 0 C hour 1 0 2 0 C hour 1 0 2 0 C hour 1 0 2 0 C hour 1 0 2 0 C hour 1 0 2 0 C hour Cable length 5 m 5 m 5 m 5 m 5 m 5 m User capacity...

Страница 9: ...illed with water and four people is approximately 1200 kg Horizontal level A horizontal surface is particularly important The water level must always be horizontal A level and horizontal surface ensur...

Страница 10: ...knives cutters etc to open the packaging to avoid damaging the film Step a Lay the ground sheet on a flat even surface free from sharp objects Uncoil the cables and plug which located under the motor...

Страница 11: ...l not to over inflate the pool If you want to refill air into a whirlpool filled with water you must first press the BUBBLE button for 2 3 minutes Then you can carry out the air filling according to s...

Страница 12: ...pool starting at the control unit The electrical connection is made by the power supply unit and connecting cable Pay attention to the groove in the plug Different colors brightness and modes can be s...

Страница 13: ...ly if it is not filled with water Caution This pool is equipped with a plug fitted with a residual current device or ground fault circuit interrupter RCD In the event of a leakage current the power su...

Страница 14: ...is button and the filter pump starts to work and the red indicator lamp lights up Press again and the pump stops working and the lamp goes out NOTE The filter pump does not switch off automatically If...

Страница 15: ...spa after use to minimize heat loss when heating the water for good heat insulation Store the cover in a suitable place where it is free from contamination or damage Note The integrated temperature s...

Страница 16: ...filling hose and close both outlets again Caution The drained water can contain chemical residues and or other unhygienic components that can have a negative impact on health and the environment Chec...

Страница 17: ...AREBOS SPA Pool 17 How to Change the filter cartridge Make sure that the mains plug has been disconnected from the power supply Unscrew the filter cartridge by turning it counterclockwise Remove the f...

Страница 18: ...al detergent The purpose of putting the filter inside a pillowcase tower is to reduce noise TIPS Smaller particles pollen dust etc can be deposited on the surface of the water which do not sink and ca...

Страница 19: ...the water treatment products in a cool dry place inaccessible to children For the disinfection of the SPA water there are different methods to choose from Always use a dosing float for dosing during...

Страница 20: ...harp corners to prevent damage Store the pool in a dry frost free place The original packaging can be used for storage Caution Plastic can become brittle and fragile when it is exposed to sub zero tem...

Страница 21: ...ter level is too low Top up the water level Dirt accumulates inside the motor Remove the filter cartridge then place the water hose at the water outlet and collect particles of dirt at the filter conn...

Страница 22: ...filter cartridge Incorrect water treatment Read the instructions of the chemical s manufacturer LED light doesn t work Where applicable Transparent tabs in remote is not removed Ensure you have remove...

Страница 23: ...r and filter 2 Remove the Filter cover and Filter 3 Place the filter cover over the filter inlet and use an elastic band to hold the filter cover in place to stop debris getting into the pump 4 Press...

Страница 24: ...due to the pipe and heater being too cold to function Make sure the filter is clean and change if necessary Pouring some hot or warm water into the hot tub either using a hot water pipe or buckets of...

Страница 25: ...ter a maximum of 300ml surrounding the heating element which is where the temperature sensor is located therefore displaying a reading that will not be reflecting the actual water temperature usually...

Страница 26: ...out other return options created by us on our website www arebos de The separate collection of Waste electrical or electronic equipment is intended to enable the reuse recycling or other forms of reco...

Страница 27: ...ive 2014 30 EU Electromagnetic Compatibility 2011 65 EU EU 2015 863 RoHS The object of the declaration described above is in conformity with the relevant European Union harmonization legislation The a...