4.8 Access code
An access code which can be set from 0000 to 9999 serves to protect
the meter and its setpoints from unauthorized programming, and to lock
the access to some functions.
0 0 0 0 Factory code
x x x x
0 to 5 Access to the display shifting
6 to 9 No access
0 to 5 Access to the display and output simulations
6 to 9 No access
0 to 5 Access to the function “tare” (except temperature inputs)
6 to 9 No access
0 to 5 Access to the quick entering of alarm setpoints
6 to 9 No access
p18
rEAd
rEAd
InPut
diSPL.
AnA.
JbuS
Pr.diS
About
4.7 Reading of the configuration
Reading of the input parameters
Reading of the measure display parameters
Reading of the analog output parameters
(option analog output)
Reading of the communication parameters
(option digital output)
Reading of the logic inputs parameters
(option TOR)
Reading of the alarm parameters
(option 2 or 4 relays)
Reading of the safety parameters for sensor
rupture or self-diagnosis of the outputs
Reading of the display programming para-
meters (the leds, bargraph led...)
Reading of the instrument internal parameters
In each reading submenu press
and
to move, and
to visualise parameters.
If no key is pressed during 20 s. the instrument will revert to the
measure display.
Validation / vertical
move
rELAY
SECU
tor
About
dIP
n0
A0123
ProG
08.00
0Pt
Ar4--.
Err.
0000
CSUM
FC4E
Validation / vertical
move
type of the instrument
Submenu
number of the instrument
programme version
code of the
installed options
error code in case of
self-diagnosis error
check sum of the flash
memory
X1 : - : no analog output
A : analog output
X2 X3 : - - : no relay output
r- : output 2 relays
r4 : output 4 relays
X4 : - : no RS output
n : RS output
X5 - : no logic input
t : 2 logic inputs
(.) : decimal point still:
no bagraph
“.” : decimal point lit:
option bargraph
XXXXX
12345
402
XXXXX
12345