p12
Thermocouple
tc-j
tc-CA
tc-n
tc-5
tc-b
tc-C5
tc-t
tc-r
tc-E
tc-C
tc-C3
tc-L
J
K
N
S
B
W5
T
R
E
W
W3
L
Accuracy in
% of the MR*
* 30µV typical (60µV max.) on the others
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
0.1 %
-160 / 1200°C
-270 / 1370°C
0 / 1300°C
-50 / 1770°C
200 / 1820°C
0 / 2300°C
-270 / 410°C
-50 / 1770°C
-120 / 1000°C
1000 / 2300°C
0 / 2480°C
-150 / 910°C
-256 / 2192°F
-454 / 2498°F
32 / 2372°F
-58 / 3218°F
392 / 3308°F
32 / 4172°F
-454 / 770°F
-58 / 3218°F
-184 / 1832°F
1832 / 4172°F
32 / 4496°F
-238 / 1670°F
Measurable limit of the input
°C
°F
4.5.4 Resistance and potentiometer inputs
• Resistance
• Potentiometer:
Caliber
Measurable limits of
the input
Accuracy in %
of the MR
0 / 400
Ω
0 / 2000
Ω
0 / 8 K
Ω
(optional)
0 / 440
Ω
0 / 2200
Ω
0 / 8.8 K
Ω
0.1%
0.5%
0.1%
Caliber
Accuracy in % of
the MR
from 100
Ω
to 10 K
Ω
0.1%
HoLd
CLr.M
tArE
Point
AnA.
F.out
dO.diS
FO.diS
d.out
4.5.5 Logic inputs
(option TOR)
• Board of 2 logic inputs: Input signal 24 Vdc
Possible functions
:
Display hold in case of activation of the logic function.
The display and the analog output remain fixed in case of
variation of the input signal. The relays keep reacting to the input
signal.
Zero reset of the min. and the max. The activation of the
logic function will reset the min. and the max. to 0.
Activation of the function tare.
The meter switches to the mode tare, the tare being the
display value present at the moment when it is activated.
Function moving of the decimal point
4.6 Features of the outputs and programming
limits
4.6.1 Analog output
0/4-20mA active or passive current output (Vmax.=30V
DC
) or
0-10V voltage output
•
Accuracy: 0.1 % in relation to the display (at +25°C)
•
Residual ripple
≤
0.2%
•
Admissible load 0
Ω
≤
Lr
≤
600
Ω
(current)
Lr
≥
5 k
Ω
(voltage)
•
Programmable scale ratio with enlarging effect
•
Response time: 40 ms in relation to the display
Indication of the output type (voltage or current)
Choice of the parameter assigned to the output for the down
and full output scale (in display points if PArA. = diSP.)
(in input scale points if PArA. = InPut.)
Down scale of the analog output (eg. 04.00 (4mA))
Full scale of the analog output (eg. 20.00 (20mA))
Display value corresponding to the output down scale
Display value corresponding to the output full scale
In mode measurement, the analog output can not overstepp 10%
of the greatest of the 2 values: d.out and F.out
In case of activation of the logic function the decimal
places itself as has been programmed.
Fct.P
PArA.
tyPE
-.---