The
DIP 10
is a high accuracy digital panel meter. It is equipped on front
face with a four 14 mm high red digits display, whose brightness suits
applications in industrial control rooms perfectly.
It allows the display, the control and the transmission of data from any
measurable magnitudes.
AVAILABLE OPTIONS
:
(specify on order)
Insulate analog output
: A
Active current output, or voltage.
Programmable scale ratio with enlarging effect.
Relay output
:R
2 relays: mode setpoint or window.
Recording of the alarms.
Time delay and hysteresis adjustable on each setpoint.
Alarm messages
CODING
:
•
Type: DIP 10
•
Output options:
A: Analog (A1 or A3: specify)
R: 2 relays
These options can be combined simultaneously
Order example:
For a panel meter with 1 active current analog output and 2 relays,
request reference DIP 10 A1R
1. INTRODUCTION
Features of the inputs
♠
A 12 µA pulsed current
allows the detection of line or
sensor rupture
Thermic drift <150ppm /°C
(1) Line resistance <25
Ω
(2) Or 30 µV typical (60µV Max.)
♦
CJC efficiency: ±0.03°C/°C
±0.5°C
from -5°C to +55°C
MR Measure range
♣
Cut off : the display and the
output remain at down scale for
an input signal < value of the cut
off, programmable from 0% to
100% of the input range.
Types of
INPUTS
Measure range adjustable
from
Permanent
overload
Intrinsic
error
Input
impedance
mA
♣
-2 to +22mA
±100mA
<
±0.05%
of the MR
Max. drop
0.9V
mV
♠
♣
-10 to +110mV
±1V
≥
1M
Ω
V
♣
-0.1 to +1.1 V
±50V
-1 to +11V
-30 to +330V
±600V
Thermocouples
♠
Standard IEC 581
J
K
B
R
S
T
E
N
L
W
W3
WRE5
°C
-160/1200
-270/1370
200/1820
-50/1770
-50/1770
-270/410
-120/1000
0/1300
-150/910
1000/2300
0/2480
0/2300
°F
-256/2192
-454/2498
392/3308
-58/3218
-58/3218
-454/770
-184/1832
-32/2372
-238/1670
1832/4172
32/4496
32/4172
-
♦
(2)
<±0.1%
of the MR
≥
1 M
Ω
Sensor Pt100
Ω
(1)
♠
3 wire, Standard
IEC 751 (DIN 43760)
°C
-200/850
°F
-328/1562
-
<±0.1%
of the MR
Current
250µA
Sensor Ni 100 3 fils
(1)
♠
-60/260
-76/500
-
Resistive sensors
Calibers 0-440
Ω
and
0-2.2 k
Ω
♣
(0-8.8 k
Ω
optional)
<±0.1%
of the MR
(0.5%
for
0-2K
Ω
)
-
Potentiometer
from 100
Ω
to
10 k
Ω
♣
Supply for 2 or 3-wire
sensor
24 V
DC
±15% with protection from
short-circuits. 25 mA max.
Special linearisation
programming up to
20 points
On input: mV, V, mA.
Resistive sensors and potentiometer