ARDETEM DIP 10 Скачать руководство пользователя страница 12

p11

Input

mA

  d.in     0

  A01     2

  A02     4

  A03     6

  A04     8 

  A05    10

  A06    12

  A07    14

  A08    16

  A09    18

  F.in    20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

0.00

73.74

106.26

132.84

156.93

180.00

203.07

227.16

253.74

286.76

360.00

0.00

0.60

0.80

0.92

0.98

1.00

0.98

0.92

0.70

0.60

0.00

0.000

0.041

0.112

0.198

0.293

0.393

0.492

0.587

0.674

0.745

0.785

d.diSP

B01

B02

B03

B04

B05

B06

B07

B08

B09

F.diSP

00.00

01.04

02.85

05.04

07.47

10.00

12.54

14.96

17.17

18.98

20.00

Height

m

Degree

Chord

m

Volume

m3

Outputs

in mA

Display of the meter

:        

Empty tank volume d.diSP = 0.000

Full tank volume F.diSP =0.785
Volume = L [

π

 R² 

β

/360 - C(R-h)/2]

Say a curve of 10 equally long segments: 

Measure range / nbr of segments = 20mA/10 = 2mA length of the 

segment. For 10 segments nb = 9 (11 points to be programmed, inclu-

ding d.in and F.in).

Programming:

d.in = 0 mA             F.in = 20 mA  

nb = 9 

d.disp = 0.000 m3  F.disp = 0.785 m3

Programming from A01 to A09 and from B01 to B09 according to the 

table.

0   2   4   6   8  10 12 14 16 18 20

0     0.1    0.2    0.3   0.4    0.5    0.6    0.7    0.8    0.9     1

20
18
16
14
12
10

8
6
4
2

0.1

0.04

0.20

0.29

0.39

0.49

0.59

0.67

0.75

0.79

volume 

in m3

output (mA)

Y

X

input (mA)

height (m)

4.6 Features of the outputs and programming limits

4.6.1 Analog output       

                                         

0/4-20mA active current output,  or  0-10V voltage output
• 

Accuracy: 0.1 % in relation to the display (at +25°C)

• 

Residual ripple 

≤ 

0,2%

• 

Admissible load 0

 

      Lr 

 600

 (current) 

                                           Lr 

≥ 

500 k

Ω 

(voltage)

• 

Scale ratio programmable with enlarging effect

• 

Response time: 40 ms in relation to the display

                

               Down scale of the analog output (eg. 04.00 (4mA))

                                Full scale of the analog output (eg. 20.00 (20mA))
                                      Display value corresponding to the output down scale
                                Display value corresponding to the output full scale
In mode measurement, the analog output can not overstepp 10% of the greatest 

of the 2 values : d.out and F.out

Out.U

Out.i

dO.diS
FO.diS

F.out

d.out

or

Содержание DIP 10

Страница 1: ...ax 04 72 31 31 31 Tel Intern 33 4 72 31 31 30 Fax Intern 33 4 72 31 31 31 ARDETEM TA IN 46 C 11 06 Any data in this documentation may be modified without prior notice ARDETEM Soucieu en Jarrest FRANCE...

Страница 2: ...12 4 6 3 Safeties p13 4 6 4 Display features p14 4 7 Reading of the configuration p14 4 8 Access code p15 4 9 Programming of a new access code p15 4 10 Functions of the the main menu p15 4 10 1 Displa...

Страница 3: ...V typical 60 V Max CJC efficiency 0 03 C C 0 5 C from 5 C to 55 C MR Measure range Cut off the display and the output remain at down scale for an input signal value of the cut off programmable from 0...

Страница 4: ...Voltage direct or reversed 0 10V Load impedance Lr 500k 2 setpoints per relay configurable on the whole MR Hysteresis programmable from 0 to 100 Time delay programmable from 0 to 25 sec 8A 250 VAC on...

Страница 5: ...transmitter VOUT GND VCC 5 6 7 Tc Pt100 3 wire Ni 100 3 wire 4 5 6 7 Potentiometer RESISTANCE AND POTENTIOMETER TEMPERATURE PROCESS Resistance 440 up to 2k 0 8k optional Strap 4 and 7 on terminal 0 4...

Страница 6: ...ation display Entering of a parameter First start by increasing or decreasing the 1st digit and the sign from 9 to 9 the 2nd from 0 to 9 the 3rd from 0 to 9 the 4th from 0 to 9 M M Alarms Led 1 Led 2...

Страница 7: ...is and or sensor rupture and access to disconnecting the sensor rupture option analog or relay output Access to the programming of the display p10 Access to the programming exit menu with p10 or witho...

Страница 8: ...d the analog output SPxx hystx do diS Fo diS If thermocouple if other than thermocouple CJC E CJ t CJC yES no AdJuS to tc diSPL tc S tc CA tc J tc r tc t tc E tc b tc n tc C tc C3 tc C5 tc L oF oC rES...

Страница 9: ...yES 88 88 1 1 setting in display points You can choose to assign the analog output to the input measure PArA InPut or to the displayed measure PArA diSPL Eg with PArA diSPL When the transmitter indic...

Страница 10: ...tus of the relay 1 in case of sensor rupture LO HI OFF status of the relay 2 in case of sensor rupture disconnection of the sensor rupt or yES no value of the output in case of sensor rupture 00 00 rE...

Страница 11: ...max as well as the alarm recordings 4 5 1 Current input Special linearisation For specific applications such as the measurement of volume the meter can memorise an unlinear curve programmable in X an...

Страница 12: ...A F in 20 mA nb 9 d disp 0 000 m3 F disp 0 785 m3 Programming from A01 to A09 and from B01 to B09 according to the table 0 2 4 6 8 10 12 14 16 18 20 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 20 18 16 14...

Страница 13: ...m as the led represents the alarm state OFF OFF OFF ON ON ON setpoints setpt setpt or SP X SP X HYSx HySt x LEdx On OFF SP1 X SP1 X HYSt x SP2 X SP2 X HYSt x SP2 X SP1 X SP2 X SP1 X led lit led lit le...

Страница 14: ...t supplied in case of sensor rupture Relay active coil supplied in case of sensor rupture Note the led is either still or lit according to its programming in the menu rELAY 4 6 3 Safeties Self diagnos...

Страница 15: ...ration indice of the digital filtering Programmable from 0 to 10 for use in case of unsteady input signal To obtain the maximum response time add 240 ms Note For the response time of the analog output...

Страница 16: ...XXXXX 1 2 3 4 5 P CodE OLd no Enter former code if code not valid old display during 2s and revert to the measure display New code registered and revert to the measure display if code correct old Ente...

Страница 17: ...orresponding led starts to blink To revert to the normal status led not blinking and relay in the correct state use menu CLEAr M CLEAr the recorded alarms are not deleted deleting of the recorded alar...

Страница 18: ...can increase or decrease the down or full display scale If you keep pressing during 3s on key or you can access a quick increasing or decreasing of the display value Press to validae the shifting The...

Страница 19: ...Setting of the setpoints There are 2 ways to adjust setpoints either in mode programming entering the correct safety access code see p15 or by pressing simultaneously on and The meter will then show...

Страница 20: ...UE Messages shown by the meter in mode programming and or in mode reading General access Access to the reading of the parameters Access to the programming of the input and output parameters Code for a...

Страница 21: ...l point in mode measure Place of the decimal point Choice of the processing function Linear Input down scale Input full scale Down and full display scale diSPL Point Funct LinEA d in F in F diSP d diS...

Страница 22: ...oints Sepoint and hysteresis in display points Operating mode of the relay x Mode setpoint Mode window Value of the setpoint in mode setpoint Value of the 1st setpoint in mode window Value of the 2nd...

Страница 23: ...ing of the instrument internal features Access to the submenu reading of the internal features Name of the instrument Type of the instrument Available options standard A analog output R relay output I...

Отзывы: