Arctiko UPUL 580 Скачать руководство пользователя страница 5

Inner doors
NOTE

The inner doors should be used at all times. Make sure to close them tightly. (figure 1)
The manufacturer is not responsible for damage to the freezer caused by failure to do so.

Electrical Connection

The machine meets current EU directives. Low voltage 2006/95/EEC.
Electromagnetic compatibility 2004/108/EEC.

The machine should be given extra protection in accordance with Electricity Supply Regulations in order to 

protect the user against dangerous electric shocks in the event of faults.

If the switch is for a three-pin plug, a three-pin plug should be used and the conductor with yellow/green 

insulation connected to the Earth terminal. 

Data regarding voltage and absorbed power/current is given on the rating plate.

Electrical connection must be made in accordance with the local regulations.

For installation see wiring diagram (page 18 - 19). 

Warning

Regulations require that this appliance be earthed:
The manufacture declines all liability for injury to persons or animals and for damage to property resulting 

from failure to observe the above procedures and reminders.

If the socket and plug are not of the same type either the socket or the plug must be replaced by a qualified 

electrician. 
Under no circumstances use extension leads or adaptors.

1.

The freezer should be connected by an authorised electrician or by the company that sold the

freezer. Incorrect installation may damage the freezer.

2. 

Place the freezer on a flat floor that can bear the weight of the freezer.

3. 

The electrical installation should be earthed.

4. 

Do not use extension cables. Connect the freezer directly to a fixed installation. If the freezer is 

connected to a long extension cable there is a risk that the cable will become hot.

5. 

The freezer should be placed in a dry location. Do not allow water to come into contact with the 

cabinet. Water entering electrical parts may cause short-circuiting.

6. 

In the event of functional or electrical irregularities, please contact an authorised service engineer.

5

Содержание UPUL 580

Страница 1: ...OPERATING INSTRUCTIONS UPUL 580...

Страница 2: ...scription of the control panel 6 Access code 6 Turn Push button 7 Main switch 7 Menu selection 7 Adjustment of settings 7 Operation description 7 Usage 8 Setup 8 Manual mode 8 Calibration of sensor 8...

Страница 3: ...ed centre for recovery of refrigerant Information This appliance contains a mixture of various refrigerants For more information please refer to the rating plate affixed to the freezer Precautions and...

Страница 4: ...rities contact professional instructors or repair technicians immediately Installing the Freezer 1 You will find 3 different plugs for the installation Use the plug suitable for your electrical connec...

Страница 5: ...pliance be earthed The manufacture declines all liability for injury to persons or animals and for damage to property resulting from failure to observe the above procedures and reminders If the socket...

Страница 6: ...not to effect the inside temperature of the unit Disconnecting the appliance Electrical disconnecting must be possible either by unplugging the appliance or by means of a double pole switch located up...

Страница 7: ...until the required parameter value is shown in the display Press once to edit the value It will now flash Turn the button to adjust the parameter Press the button to accept the value or cancel it by...

Страница 8: ...eezer temperature rises above SetPoint TDiff they will start up again Please note that the fan will run 15 seconds before and after the compressor Manual mode A person with the correct access code wil...

Страница 9: ...he Alarm Menu can be activated Delete an inactive alarm from the list by pushing the Turn Push Button Active alarms cannot be acknowledged In the ALARM LOG sub menu the last 16 alarms can be read If t...

Страница 10: ...n the set temperature and the temperature shown will be the same CO2 Back Up 2 4 x port holes are prepared for CO back up and an injection tube see separate enclosure can be inserted 2 from the top of...

Страница 11: ...is not recommended to lay down the unit Please let the unit rest in vertical position for minimum 12 hours before start up Cleaning and Maintenance of the Freezer Ice will form on the inner doors of t...

Страница 12: ...e unit type number and the function of the part s concerned Disposing of the Freezer To prevent harmful environmental effects contact the distributor and ask where the freezer should be delivered Remo...

Страница 13: ...button for 10 seconds Can also be done by the user This menu is applied by the technician to decide whether the freezer should run automatically or manually View menu shows set point and the number of...

Страница 14: ...this menu the technician can programme the freezer to run automatically or manually Back to previous menu Shows current set point Shows how many alarms are saved in the alarm log Back to previous menu...

Страница 15: ...ing of the lowest alarm limit TA1Lo TSet Alarm The programming of the highest alarm limit TA1Hi TSet Alarm The delay of the abovementioned alarms starts The technician has to programme the maximum all...

Страница 16: ...with reference to the alarm Shows the last 15 alarms Back to previous menu Back to previous menu Shows which software version is installed in the unit Shows the total running hours of compressor Shows...

Страница 17: ...of Fan Manual running of light Manual running of CTS Test of Power Sence Relay When this relay runs out it is discovered by D12 Test of battery and test of Battery Disconnect Relay Manual running of...

Страница 18: ...18 CONNECTION DIAGRAM...

Страница 19: ...19...

Страница 20: ...LAMMEFJORDSVEJ 5 DK 6715 ESBJERG N DENMARK TEL 45 70 20 03 28 FAX 45 70 20 03 29 INFO ARCTIKO COM WWW ARCTIKO COM WWW ARCTIKO COM 50 80 014 xx GB...

Отзывы: