Arctiko ULUF Скачать руководство пользователя страница 5

Installation

Preparing the appliance

Unpack the appliance:

 -

 Remove all packaging materials, plastic bags and  

   straps.

Storing the key: 

- The key for the door lock is placed strapped to the main 

  cable in the compressor compartment. Remove the key from the cable 

  carefully without causing damage to the cable. Keep the key in a safe place.

Read the Quick start guide: 

-

 The quick guide is provided with the appliance.

Ventilate the appliance: 

Open the door for at least 20min in order to 

  ventilate the appliance before first use. The appliance may contain odors 

  from manufacturing.

Clean the appliance

: - 

Clean the appliance on the inside and outside with a 

  soft cloth/sponge using a solution of water and light detergent. After cleaning 

  all surfaces of the appliance, wipe the inside with a dry rag.   

Remote alarm contact:  

- The terminals for the remote alarm contact are 

  located in the compressor compartment  (see “Cabinet description”). 

  The contact is designed for a maximum load of 2A and 30VDC. The remote   

  alarm contacts work in synchronization with the acoustic alarm on the 

  appliance. In order to cancel the remote alarm push the “Enter” button.  

  However, in case of a power outage, the remote alarm contact cannot 

  be controlled by the control panel of the appliance. The remote alarm can be 

  set as normally open (NO) or normally closed (NC).

Refrigerant

Please see the rating plate affixed to the appliance to obtain information about 

the refrigerant.

 

 Location

Place the appliance in a location that satisfies the following conditions in or-

der to achieve optimal operating results:

Firm and levelled floor:

 - Placing the appliance on a firm and flat floor 

  reduces the risk of excessive noise and vibration.

Away from any heat sources: 

-  Avoid placing the appliance near any heat 

  dissipating devices such as a gas burner/stove, radiator, oven or other 

  source of heat. Exposing the appliance to heat will lower the performance.

-

 Place the appliance away from direct sunlight:

 

Placing the appliance in  

  direct sunlight may cause reduced performance and shorten the life 

  expectancy. 

-

 Dry area:

 - 

 Avoid placing the appliance near damp areas such as near water 

  faucets and sinks.

Clean area:

 - 

 Placing the appliance in a clean environment will reduce risk  

  of function failure. Avoid installing the appliance in or near chemicals and  

  materials that might have outgassing property to avoid corrosion.

- Well ventilated:

 There must be sufficient space around the appliance to 

ensure air ventilation. Lack of such space will reduce the cooling 

capability of the appliance.

Do not place any objects on top of the appliance.

!

8

9

An electrical power plug with a ground prong must be used to 

power the appliance. 

This is to prevent electrical shock.

Do not use the appliance outdoors.

 

Current leakage or electric shock may result if the appliance is 

exposed to rain.

!

Never install the appliance in a flammable or volatile location. 

This may cause explosion or fire.

Install the appliance on a sturdy floor and take an adequate 

precaution to prevent the appliance from tipping.

Содержание ULUF

Страница 1: ...ORIGINAL OPERATING INSTRUCTIONS ULUF models Ultra low temperature freezers 90 C Ultra low temperature freezers 86 C Low temperature freezers 40 C...

Страница 2: ...her information about the appliance Symbols Abbreviations Safety Intended use Personal safety Handling Transportation Moving the appliance Packaging Unpacking Inactivity for extended period Disposal I...

Страница 3: ...the advantages of your appliance To meet the high quality demands required by the medical and pharmaceutical industry at least 10 of all appliances leaving Arctiko are carefully checked and tested to...

Страница 4: ...te the appliance and make sure it is completely dry Disconnect the power cord Leave the door slightly open in order to prevent rot and mold Disposal In the event of disposal of the appliance observe r...

Страница 5: ...ut the refrigerant Location Place the appliance in a location that satisfies the following conditions in or der to achieve optimal operating results Firm and levelled floor Placing the appliance on a...

Страница 6: ...on must always be secured with a minimum 10 A fuse If more than one appliance needs to be installed each appliance must be connected to an individual fuse group When installing the appliance make sure...

Страница 7: ...w and low temperature freezing with high performance and stability Standard features is filter less construction for less maintenance low noise level low energy consumption low heat dissipation and ex...

Страница 8: ...ion Never insert probes through the door as this will danger the door gasket increase the ice build up and affect the temperature inside the appliance Display G214 The control panel is a multifunction...

Страница 9: ...lay is mounted in the top panel 17 Push the button in order to access a temperature graph Push the buttons to navigate the data history for up to 10 days Push the Esc button in order to exit the menu...

Страница 10: ...as a backup guaranteeing that your stored products will be kept at the set temperature An Arctiko appliance which offers dual cooling system can be identified by the denomination of D in the end of t...

Страница 11: ...set between the minimum and maximum value 21 Controller operation settings Custom settings Advanced Settings Advanced service settings Status Change Reset password 20 How to change the setpoint Alarm...

Страница 12: ...imit for a period longer than the Alarm delay the low temperature alarm is activated If products with a lower temperature than the low temperature alarm setting is placed against or close to the tempe...

Страница 13: ...r will not be reactivated by accepting the alarm Recommended actions If it is a non recurring alarm the compressor can be reactivated by restarting the appliance switching the appliance off and on aga...

Страница 14: ...27 Select language The default language of the controller is English The language can be changed in the Select language menu The available languages are English German Russian French Spanish Swedish...

Страница 15: ...optional extra probes Probe 2 and Probe 3 for temperature monitoring The chamber probe is measuring the air temperature inside the appliance to control the operation of the cooling system when the co...

Страница 16: ...fect the performance of the appliance negatively or cause damage to the appliance The technical data can be found on Arc tiko s website or by contacting the seller of the appliance 31 Service The serv...

Страница 17: ...ess Hysteresis Press ENTER to access Temp range limits ATTENTION Do not change the hysteresis setting without contacting a service representative Use to choose probe Press ENTER to access Use to chang...

Страница 18: ...ory setting 0000 In order to reset the password you need to require a reset password from your Arctiko distributor Contact your distributor for the code needed Press ENTER to access menu Press until C...

Страница 19: ...or similar software This function also makes it possible for a service technician to analyze the data for troubleshooting in case of malfunctions for quick and accurate support Insert USB drive in th...

Страница 20: ...eadout has been preformed each readout will create a set of files with the number increased by one The data00 txt file contains the most recent download The param00 txt file contains the parameter set...

Страница 21: ...d Compressor alarm Marked with H if triggered Manual defrost Marked with H if cycle is running Auto defrost Marked with H if cycle is running Measurements tmp1 Temperature measured by 1st probe tmp2 T...

Страница 22: ...rost Freezer 0 Manual defrost Freezer OK Hysteresis Freezer 2 0 Temp range limits Freezer Max 20 0 Freezer Min 40 0 42 Default settings ULUF 15 65 125 Description Arctiko default settings Customer set...

Страница 23: ...0 Manual defrost Freezer OK Hysteresis Freezer 2 0 Temp range limits Freezer Max 40 0 Freezer Min 85 0 44 Default settings ULUF 490 490 2M 590 590 2M 890 890 2M Description Arctiko default settings Cu...

Страница 24: ...mends a thorough examination twice a year and cleaning at least once a month General maintenance Perform following at least twice a year Lubricate hinges and gaskets Wipe off all excess lubricant Make...

Страница 25: ...ter can damage the insulation materials and electrical components Dust off the inside of the compressor compartment using only a dry brush or a vacuum cleaner Parts of the refrigeration system of this...

Страница 26: ...m the sunlight or heat source Frequent door openings may cause the temperature to rise Check if there has been frequent door openings Leave the door closed until the temperature in the appliance is st...

Страница 27: ...5080038 11 GB...