![Arctic Cat 2014 Prowler HDX Скачать руководство пользователя страница 138](http://html1.mh-extra.com/html/arctic-cat/2014-prowler-hdx/2014-prowler-hdx_service-manual_2965410138.webp)
135
RESISTANCE
NOTE: For these tests, the meter selector should
be set to the OHMS position.
Primary Winding
1. Connect the red tester lead to the terminal (with the
wire removed); then connect the black tester lead to
ground.
PR278A
2. The meter reading must be within specification.
Secondary Winding
1. Connect the red tester lead to the high tension lead
(with the plug cap removed); then connect the black
tester lead to either primary terminal.
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace ignition coil.
Spark Plug Cap
1. Connect the red tester lead to one end of the cap;
then connect the black tester lead to the other end of
the cap.
AR603D
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace the spark plug cap.
VOLTAGE
Primary Coil
1. Set the meter selector to the DC Voltage position;
then disconnect the two wires from the coil.
NOTE: The coil is located to the right of the
engine and may be accessed from behind the
right-side seat with the cargo box raised.
2. Connect the red tester lead to the orange wire and the
black tester lead to the blue/white wire.
3. Turn the ignition switch to the ON position. The
meter must show battery voltage.
EFI Sensors/Components
CRANKSHAFT POSITION (CKP)
SENSOR
To test the CKP sensor, see Stator Coil/Crankshaft Posi-
tion (CKP) Sensor in this section.
OXYGEN (O2) SENSOR
The Oxygen Sensor (O2 Sensor) is located in the exhaust pipe.
NOTE: When testing the resistance of the sensor’s
heater, the engine/exhaust pipe must be at room tem-
perature (65-75° F) or inaccurate readings will occur.
1. Open the cargo box; then remove the seat, air filter
cover, and air filter.
2. Remove the backrest and seat base.
3. Disconnect the sensor.
HDX 247
NOTE: For this test, the meter must be in OHMS
position.
5. On the sensor side of connector, connect the black (nega-
tive) test lead to one white wire pin; then connect the red
(positive) test lead to the other white wire pin. Readings
should be between 6.7 and 10.1 ohms.
NOTE: If the meter does not read as specified,
replace the sensor.
CAUTION
Always disconnect the battery when performing resis-
tance tests to avoid damaging the multimeter.
Содержание 2014 Prowler HDX
Страница 1: ...PROWLER HDX ROV SERVICE MANUAL 2014...
Страница 3: ......
Страница 192: ...Printed in U S A Trademarks of Arctic Cat Inc Thief River Falls MN 56701 p n 2259 861...