Precautions:
6
Always use gloves when servicing the unit.
6
Check UV lamp, quartz sleeve, cord, and plug to ensure that
they are not damaged prior to installation.
6
UV Systems are designed for continuous operation. Frequent
on/off switching will reduce ultraviolet radiation and service
life and will void warranty.
6
If the UV kit falls into water, turn main power off before
retrieving it. Do not attempt to use this UV kit if it has been
submerged in water.
6
Always disconnect the water supply and completely drain
the water filter when temperatures drop below freezing for
extended periods of time.
6
Never look directly at the UV lamp while device is in
operation.
6
Disconnect power supply before servicing.
6
Make sure to only use outlets with GFI protection.
5.
UV Installation Assembly
UV Specs:
6
Consumed Power: 22W
6
Input: 110V, 50/60Hz
6
Ambient Water Temperature: 36°F-110°F
6
Iron: <0.3ppm (0.3mg/l)
6
Hardness: <7gpg (120mg/l)
6
Turbidity: <1NTU
6
Manganese: 0.05ppm (0.05mg/l)
6
UV Transmittance: >75%
The ARCS system is designed to ONLY treat condensate runoff water, DO NOT attempt to use ARCS to
treat any other water source.
To ensure maximum quality, filter housings should be replaced every three years.
The minimum flow rate to activate the ballast is 300ml/min. If the flow rate is less than 100ml/min,
the ballast will turn off.
System Maintenance:
6
Test monthly or before each use.
6
Lamp replacement is recommended every 8,000 hours
of operation.
6
Clean the quartz sleeve every 6 months with alcohol.
6
Is recommended to use gloves when replacing bulb as
contact can leave oil on its surface.
outlet
(closed)
Typical Installation
Flow sensor
inlet (open)
(open)