13
3.1.10 Output Terminals
Select output cable size based on table 3.0 below.
Duty cycle(%)
Current (A)
Length (Ft)
Cable Size (AWG)
30
180
1 – 50
8
60
300
1 – 150
1/0
60
300
150 – 200
2/0
TABLE 3.0
FIGURE 3.1
(Similar model used for illustration purposes)
RANGE SWITCH
3.1.3
POWER ON
INDICATOR
3.1.7
PROCESS SWITCH
STICK
”LIFT START” TIG
3.1.6
WELD POWER
3.1.4
ARC FORCE
3.1.5
CIRCUIT BREAKER
(POWER ON/OFF)
3.1.1
OUTPUT TERMINALS
3.1.10
INPUT POWER
CORD
25 FT (8.2m) LONG
3.1.9
THERMOSTAT
CONTROLLED
VENTILATION
3.1.2
Содержание IRONHORSE 300S