42
Notes:
1. It starts to operate if Frz Eva sensor is colder than -5C or after maximum 5 minutes.
2. When freezer fan operates, it will not stop until the compressor stops.
3. It stops when FRZ Door opens.
11.5
FF heater
Operation Conditions
FF Heater turns ON when:
- FF Air <= cut-in
FF Heater turns OFF when:
- FF Air >= cut-out
11.6
Compressor
Operation Conditions
Compressor turns ON when:
- FRZ Air >= cut-in
- FF Air >= cut-in
Compressor turns OFF when:
- Defrost status
- FF Air <= cut-out and Frz Air <= cut-out and frz and ff defrosts
Notes:
Compressor pause time = 6 minutes.
11.7
Ionizer
Operation Conditions
Ionizer turns ON / OFF when:
If FF door is not opened after the product is energized, Ionizer starts running 4+8 hours later.
If FF doors are opened and closed after the product is energized, Ionizer starts running after
the FF door is closed. It does not run when FF door is open.
Ionizer runs together with FF Fan for 30 minutes.
If FF Fan stops when Ionizer is running before 30-minute time is over, this period is
completed as 30 minutes in the next operation of FF Fan.
If FF door is not opened/closed, Ionizer will start every 8 hours.