Flex Mini-M Instruction Manual
August 2021 v1.0
Page 16 of 38
ON DIP
S2 DIP 10
ON DIP
ON DIP
ON DIP
S2 DIP 10
B. Receiver-to-Transmitter Pairing (Manual Mode):
1. Set transmitter dipswitch position 7~9 on transmitter to “100”.
2. Reinsert batteries and press any pushbutton to proceed.
3. Status LED displays firmware version with red, green and orange blinks.
4. Set receiver S2 dipswitch position 10 to “0” for manual remote pairing mode.
5. Output data (receiver) by press and hold the PAIRING button on receiver.
6. Receive data (transmitter) by press and hold PB3 (Status LED blinks green).
7. When the transmitter Status LED turns to constant green while both PB3 and the
PAIRING button are still pressed down the pairing is completed.
→
→
S2 dipswitch position 10 set to “0” Output data – receiver
Receive data – transmitter
(press and hold the Pairing button) (press and hold PB3)
8. Exit receiver-to-transmitter manual remote pairing mode by reset transmitter
dipswitch position 7~9 to “000”.
Important Note:
Make sure the pairing process is executed within distance of 10 meters from one another and
no other active receivers nearby. During pairing process, the receiver MAIN outputs must be
deactivated.
PB3