Doc No. 740048
7
MODEL 96
TUBE TO TUBESHEET WELD HEAD
OPERATION MANUAL
2.0
CABLE HOOK UP
(contd.)
Fig. 4
3.4 Slide the boots together securely to protect the connectors and fittings
from dirt, and to prevent the power and ground connectors from
coming in contact with each other. Fig. 4.
3.4 Before connecting the air line, first be sure that the air actuation
switch on the handle is in the up (off, un-actuated) position. See
fig. 6. Connect the air line to a clean, dry air source of 90-120
PSI (6.2 – 8.3 Bar).
4.0 ROTATION (SPEED) AUTO-CALIBRATION
Before welding, the electrode rotation motor must be calibrated to the
power supply. Most power supplies include an auto calibration function in
the software. Refer to the power supply operation manual for specifics on
auto calibration. The Model 96 has a maximum travel speed of 10.0 RPM
Should the power supply indicate that the weld head requires
calibration adjustment, the calibration potentiometer can be
accessed through a hole to the right of where the cable is attached.
See fig. 5
Содержание M96
Страница 1: ...M96 WELD HEAD OPERATION MANUAL...