MODEL 96  

TUBE TO TUBESHEET WELD HEAD  

OPERATION MANUAL 

 

 
6.0 ELECTRODE GEOMETRY AND INSTALLATION 

(Cont’d.) 

           

        

 

                                            Fig. 11 
 

7.0 GAS CHAMBERS 
 
 

The Model 96 features a cylindrical gas chamber to surround the 

           weld, providing excellent gas coverage. The weld head comes with 
           an opaque chamber. A clear glass chamber that can aid in weld 
           schedule development (as it allows the operator to see the weld puddle 
           being formed), is available as an optional accessory. 

 
7.1 

To remove the chamber, first release the two side latches, and 

                      remove the nose ring.  Grip the chamber and twist it while pulling it 
                      away from the weld head. 

 
7.2      Install the gas chamber by pressing it onto the O-ring in the 

                      housing. Be sure it is fully seated. Applying a very thin film 
                      of light oil or O-ring lube to the top of the chamber (on the I.D.) or to 
                      the O-ring will make installation and removal easier. 

 
        
 
 
 
 
 
 
 

Содержание M96

Страница 1: ...M96 WELD HEAD OPERATION MANUAL...

Страница 2: ...ut notice WARNING The nature of the GTAW process creates some POTENTIAL HAZARDS In accordance with international safety regulations the EXCLAMATION SYMBOL indicates that this equipment is considered H...

Страница 3: ...3 2 0 Unpacking 4 3 0 Cable hook up 5 4 0 Rotation speed Calibration 7 5 0 Mandrel installation 9 6 0 Electrode geometry installation 11 7 0 Gas chambers 15 8 0 Nose ring 16 9 0 Shielding gas 17 10 0...

Страница 4: ...ectrode maintains a constant electrode to work arc gap distance as it rotates around the joint A gas chamber surrounds the arc and weld joint providing excellent shielding gas coverage This chamber ca...

Страница 5: ...ap distance from electrode tip to tube is automatically set The electrode holder is mounted on a pivot arm which swings in or out to accommodate various tube diameters The integral 10ft 3 meter cable...

Страница 6: ...on cables may also be used The use of an extension cable does not eliminate the requirement for an adapter If an extension cable is used it is connected between the power supply and the adapter After...

Страница 7: ...ket head screw to allow the latch to open far enough to fully seat the two fittings Once the fittings are latched together lightly tighten this screw to prevent accidental disconnection See fig 2 Fig...

Страница 8: ...ion See fig 6 Connect the air line to a clean dry air source of 90 120 PSI 6 2 8 3 Bar 4 0 ROTATION SPEED AUTO CALIBRATION Before welding the electrode rotation motor must be calibrated to the power s...

Страница 9: ...eld head motor is manually calibrated by creating a weld program that should rotate the electrode 360 degrees ie 1 RPM for a total of 60 seconds 2 RPM for a total of 30 seconds 3 RPM for a total of 20...

Страница 10: ...es slow it down by turning the potentiometer counter clockwise CCW Should the rotation be too slow stopping before it reaches its start location rotating less than 360 degrees turn the potentiometer c...

Страница 11: ...he mandrel and slide the mandrel shaft into the center hole next to the electrode holder Slowly rotate the mandrel until the threaded end protrudes through the top of the weld head Reinstall the washe...

Страница 12: ...25 4mm long electrode properly installed in the electrode holder will stick out the same distance as the feet or tabs on the nose ring which sits on the surface of the tubesheet Use this 1 000 25 4mm...

Страница 13: ...0 020 0 030 0 50 76mm 0 010 0 020 25 50mm 0 036 0 083 91 2 1mm 0 030 0 050 76 1 3mm 0 020 0 030 50 76mm 0 084 0 250 2 1 6 3mm 0 050 0 070 1 3 1 8mm 0 030 0 040 76 1 0mm Fig 8 6 6 Loosen the socket hea...

Страница 14: ...th the centerline of the electrode either in line with the tube O D or slightly outside the tube O D CAUTION POSITIONING THE ELECTRODE TOO CLOSE TO THE TUBE I D CAN CAUSE THE WELD PUDDLE TO ROLL INTO...

Страница 15: ...EOMETRY AND INSTALLATION Cont d Fig 10 6 11 Once the electrode is positioned properly you can measure the distance across the electrode and the mandrel using a veneer caliper or other accurate measuri...

Страница 16: ...schedule development as it allows the operator to see the weld puddle being formed is available as an optional accessory 7 1 To remove the chamber first release the two side latches and remove the no...

Страница 17: ...tubesheet The nose ring that comes standard with the head is considered a generic nose ring and can be used for multiple applications Shown in Fig 12 For applications that require higher levels of pur...

Страница 18: ...shielding gas used is Argon Gas mixtures of 95 Argon 5 hydrogen or 75 helium 25 argon are sometimes used to achieve deeper penetration Consult the factory for recommendations The Model 96 is designed...

Страница 19: ...nternals Although you may not be storing the adapter and or extension cables leave them hooked up to the weld head when purging out the water 10 1 To drain the coolant from the weld head and cables us...

Страница 20: ...welded cleanliness of the materials being welded is of upmost importance Dirt oil paint hydraulic fluid oxidation or any other contaminant must be removed from both the tube and the tubesheet prior t...

Страница 21: ...04 0 68 0 74 I D 17 3 18 8mm 13961000 06 0 74 0 80 I D 18 8 20 3mm 13961000 09 0 80 0 84 I D 20 3 21 3mm 13961001 08 0 83 0 88 I D 21 1 22 4mm 13961001 02 0 88 0 93 I D 22 4 23 6mm 13961001 01 0 92 0...

Страница 22: ...gs are designed for specific tube sizes tube spacing and tube pattern square or tri pitch Please contact the factory for recommendations Extension Cables The use of an extension cable does not elimina...

Отзывы: