Doc No. 740048
18
MODEL 96
TUBE TO TUBESHEET WELD HEAD
OPERATION MANUAL
10.0 CLEANING AND MAINTENANCE
If the weld head is to be stored for more than 1 month, the residual water or
water/coolant mix should be purged from the hoses and weld head to
minimize internal corrosion. This is also important if the weld head is to be
stored where the temperature might fall below freezing, as trapped water
can freeze and damage weld head and/or hose internals.
Although you may not be storing the adapter and /or extension cables,
leave them hooked up to the weld head when purging out the water.
10.1 To drain the coolant from the weld head and cables, use Arc
Machines, Inc. fitting part number 294-PB-06. Unplug the water
“supply” line from the cooling unit, (leaving the water “return” line
connected to the cooling unit) and attach the (female) fitting
(294-PB-06) to the disconnected “supply” line. See Fig. 13.
Fig. 13
10.2 Using a pressurized air source of maximum 20 PSI, (139 Kp)
(1.38 Bar) blow air into the fitting to force the water out of the
cables and weld head, and back into the cooling unit. See fig. 13.