8
►
If a device without a connector is directly
connected to the fixed electrical installa
-
tions: install an isolator in accordance with
the local provisions for mains disconnec-
tion.
►
Operate the device
only with the approved
voltage (see type plate).
►
Store and transport the device
only in the
protective packaging.
Complaint
►
Contact the supplier.
Disposal
►
Packaging and any parts that are not nee
-
ded should be recycled or disposed of pro
-
perly. Observe local regulations.
Technical features (see type plate)
•
Corresponds to the standard EN 60 730-1,
-2-9
Nominal voltage
230 V AC
Cable cross section
2 x 1.5 mm²
Maximum switching
capacity
1800 W
Resilience of the
contact
8 A / 250 V ~ at cos
φ
= 1
or
2 A / 250 V ~ at cos
φ
= 0,6
Power consump-
tion in the stand-by
mode
approximately 0.6 W
Insulation type
Thermostat
Protection class II
Protection type
wall outlet
IPX4 after proper
installation
Protective areas in rooms with bath
or shower facilities (for installation
examples, see Fig. A)
•
According to national installation stan-
dards (in Germany DIN VDE 0100-701) elec
-
trical equipment may only be installed in
specific areas in rooms with bathtubs or
shower facilities.
•
Electrical equipment is permitted in the
rooms referred to above if it is protected by
a residual current protective device (RCD)
(in Germany according to DIN EN 61008-1
(VDE 0664-10)).
•
Electric devices are to be installed such that
the switches and other control and/or regu-
lation equipment cannot be touched by a
person in the bathtub or the shower.
•
Sockets, switches and control units (ther
-
mostat WKS) may only be installed outside
the protective areas.
•
Note:
the manufacturer does not approve
the installation of products in protective
area 1.
►
Install the following products only in pro
-
tective area 2 or outside the protective are
-
as:
–
radiator with heating element (DIN
55900 note "coatings for radiators".)
–
Wall outlet IPX4
Installation
Preparatory activities
►
Ensure that a outlet socket is there within
the reach of the cable of the heating ele-
ment.
►
Ensure that there is an additional outlet
socket with power supply (230 V, fuse B16
A) at the location provided for inserting the
thermostat.
A line connection is necessary between the
two outlet sockets.
To install device inserts, it is advisable to use
outlet sockets with an installation depth
≥
40 mm and diameter of 68 mm.
The outlet sockets must be freely accessible
and may not be in the projection surface of
the radiator.
►
Install radiator and heating element.
Install thermostat and wall outlet
►
Check the delivery for completeness and
damages (see Fig. B).
►
Install thermostat according to Fig.
C1 / C5
.
►
Install wall outlet according to Fig. C1 / D1-
D2.
Electrical connection
The device may only be connected by an elec
-
trical specialist.