Control and indicator elements

2

3

6

5

1

4

1  Temperature controller 

 

room temperature approximately 7–27 °C

 

 radiator temperature approximately 
40–65 °C

2  Scale of the temperature controller
3  Boost button
4  LED display mode 
5  LED display operating state fil pilote 

(country-specific)

6  LED display operating state fil pilote 

(country-specific)

Functions / operation

Comfort mode - temperature regulation

In  the  comfort  mode,  the  thermostat  retains 

the temperature level by switching the heating 
element on and off constantly. 

 

Set  the  desired  room  temperature  or  the 
temperature  level  of  the  radiator  on  the 

temperature controller (1). 

The "

" position on the scale (2) indicates the 

antifreeze setup. 

Boost mode

In the boost mode, regardless of the set tem-
perature level, the heating element heats con-

tinuously for 60  minutes. The thermostat then 

switches back to the comfort mode. 

 

To activate the boost mode or early cancel

-

lation, press the button (3) briefly.

For safety reasons, the thermostat switches off 
on  reaching  a  room  temperature  of  approxi

-

mately  28  °C  (room  temperature  regulation 
mode) or approximately 35 °C (towel warming 

mode).

Display

LED display 
mode (4)

Meaning

Lights red

Heating phase

Lights yellow

Setpoint temperature has 
been reached, heating ele-
ment is switched off

Blinks red

Boost mode is active

EN – Installation instructions

The device may only be connected by an elec

-

trical  specialist.  An  electrical  specialist  is  so-
meone  whose  technical  training,  knowledge, 

experience  and  knowledge  of  the  relevant 

regulations allows him to assess the tasks assi-
gned to him and recognise potential hazards.

Safety instructions

 

Read these instructions thoroughly prior to 

installation and commissioning. 

 

After  installation  pass  the 

instructions  on 

to the end used

 WARNING 

Danger of death from electric shocks! 

 

Install and connect the device

 

only in the 

de-energized state. 

Operating conditions

 

Install  thermostat  only  in  conjunction 

with  electrical  heating  elements  from  the 
manufacturer's product range.

 

When installing in rooms with bath or sho-
wer facilities: take into account protective 
areas  according  to  national  installation 

standards (in Germany DIN VDE 0100-701). 

Also follow all local regulations. 

 

When installing

 

, provide an on-site residu-

al-current-operated protective device (with 
trigger limit less than or equal to 30 mA).

Содержание WKS

Страница 1: ...r l l ment chauf fant lectrique 2013 08 6912014 AKP Arbonia AG Amriswilerstrasse 50 CH 9320 Arbon T 41 71 447 47 47 F 41 71 447 48 47 www arbonia ch AKP AFG Arbonia Forster Riesa GmbH Heinrich Sch nbe...

Страница 2: ...sichtigt oder bez g lich des sicheren Gebrauchs des Ge r tes unterwiesen wurden und die daraus resultierenden Gefahren verstehen Kinder j nger als 3 Jahre sind vom Ger t fernzuhalten es sei denn sie w...

Страница 3: ...rmen in Deutschland DIN VDE 0100 701 beachten Dar ber hinaus alle rtlichen Vorschriften beachten Bei der Installation eine bauseitige Fehler stromschutzeinrichtung vorsehen Ausl se grenze kleiner glei...

Страница 4: ...llieren dass Schalter und andere Regel und oder Steuereinrichtungen nicht von einer Person in der Wanne oder der Dusche ber hrt wer den k nnen Steckdosen sowie Schalt und Steuerger te Thermostat WKS d...

Страница 5: ...rten LED 4 zeigt durch gelbes Blinken die Umstellung an Die Anzeige der Betriebsart erlischt Betriebsart Handtuchw rmen ist aktiv Rahmen Skalenblende 2 und Temperatur regler 1 wieder aufsetzen Wird an...

Страница 6: ...ove 8 years under supervision or they are in structed regarding the safe use of the device and understand the risk resulting therefrom Children less than 3 years are to be kept away from the device un...

Страница 7: ...re regulation mode or approximately 35 C towel warming mode Display LED display mode 4 Meaning Lights red Heating phase Lights yellow Setpoint temperature has been reached heating ele ment is switched...

Страница 8: ...ctive device RCD in Germany according to DIN EN 61008 1 VDE 0664 10 Electric devices are to be installed such that the switches and other control and or regu lation equipment cannot be touched by a pe...

Страница 9: ...e the frame the dial 2 and the tem perature controller 1 carefully Set the rotary switch 7 to the 1 position LED 4 mode displays the conversion by blinking yellow Display of the operating mode goes ou...

Страница 10: ...i o se istruiti sull uti lizzo sicuro dell apparecchio e in grado di capire i pericoli che posso no sorgere I bambini di et inferiore ai 3 anni devono essere mantenuti lontani dall apparecchio a meno...

Страница 11: ...ticipatamente premere breve mente il tasto 3 Per motivi di sicurezza il termostato si spegne al raggiungimento di una temperatura am biente di circa 28 C tipo di esercizio regola zione della temperatu...

Страница 12: ...ezione presa dell aria a muro IPX4 secondo un mon taggio corretto Zone di protezione in locali con vasca o doccia esempi di applicazione vedere fig A In base alle norme di installazione naziona li in...

Страница 13: ...a una regolazione della temperatura del radiatore dipendente dalla temperatura ambiente ad esempio perch la temperatura ambiente viene regolata da una riscaldamento superficiale eseguire i seguenti pa...

Страница 14: ...nt t instruits sur une utilisation s curis e de l appareil et s ils comprennent les dangers encourus Les enfants de moins de 3 ans doivent tre tenus l cart de l appareil moins d tre sous sur veillance...

Страница 15: ...gl en mode Boost l l ment chauffant fonctionne de mani re continue pendant 60 minutes Ensuite le thermostat revient en mode Confort Pour activer ou interrompre pr matur ment le mode Boost appuyer bri...

Страница 16: ...Toujours entreposer et transporter l appareil dans son emballage de protec tion R clamation S adresser au fournisseur Traitement des d chets Apporter l emballage et les pi ces non uti lis es dans un...

Страница 17: ...de protection vert jau ne FP fil pilote noir sur site C4 au besoin et avant le montage des cou vercles r gler le mode de fonctionnement selon fig F1 F3 R glage du mode de fonctionnement l tat de livr...

Страница 18: ...18 1 0 2 2 1 0 A B...

Страница 19: ...19 40 mm D1 C1 D2 1 2 3 C4 C5 C3 C2...

Страница 20: ...20 L L N N FP N L fil pilote optional L L N PE N FP N L E2 E1 2 1 0 1 2 3 4 5 7 3 4 1 2 2 1 F2 F3 F1...

Отзывы: