7
Control and indicator elements
2
3
6
5
1
4
1 Temperature controller
room temperature approximately 7–27 °C
radiator temperature approximately
40–65 °C
2 Scale of the temperature controller
3 Boost button
4 LED display mode
5 LED display operating state fil pilote
(country-specific)
6 LED display operating state fil pilote
(country-specific)
Functions / operation
Comfort mode - temperature regulation
In the comfort mode, the thermostat retains
the temperature level by switching the heating
element on and off constantly.
►
Set the desired room temperature or the
temperature level of the radiator on the
temperature controller (1).
The "
❄
" position on the scale (2) indicates the
antifreeze setup.
Boost mode
In the boost mode, regardless of the set tem-
perature level, the heating element heats con-
tinuously for 60 minutes. The thermostat then
switches back to the comfort mode.
►
To activate the boost mode or early cancel
-
lation, press the button (3) briefly.
For safety reasons, the thermostat switches off
on reaching a room temperature of approxi
-
mately 28 °C (room temperature regulation
mode) or approximately 35 °C (towel warming
mode).
Display
LED display
mode (4)
Meaning
Lights red
Heating phase
Lights yellow
Setpoint temperature has
been reached, heating ele-
ment is switched off
Blinks red
Boost mode is active
EN – Installation instructions
The device may only be connected by an elec
-
trical specialist. An electrical specialist is so-
meone whose technical training, knowledge,
experience and knowledge of the relevant
regulations allows him to assess the tasks assi-
gned to him and recognise potential hazards.
Safety instructions
►
Read these instructions thoroughly prior to
installation and commissioning.
►
After installation pass the
instructions on
to the end used
.
WARNING
Danger of death from electric shocks!
►
Install and connect the device
only in the
de-energized state.
Operating conditions
►
Install thermostat only in conjunction
with electrical heating elements from the
manufacturer's product range.
►
When installing in rooms with bath or sho-
wer facilities: take into account protective
areas according to national installation
standards (in Germany DIN VDE 0100-701).
Also follow all local regulations.
►
When installing
, provide an on-site residu-
al-current-operated protective device (with
trigger limit less than or equal to 30 mA).