20
Technical features (see typeplate)
•
Corresponds to the standard EN 60730-1,
-2-9
•
Batteries thermostat: 4 x 1.5 V, type LR6 or
AA
•
Radio frequency: 868 MHz
Performance data radio receiver
Nominal voltage
230 V AC
Cable cross section
1 x 1.5 mm²
recommended wire
end ferrules
L = 10 mm according to
DIN 46228
Maximum swit
-
ching capacity
1800 W
Resilience of the
contact
8 A / 250 V ~ at cos
φ
= 1
or
2 A / 250 V ~ at cos
φ
= 0,6
Power consumpti-
on in the stand-by
mode
approximately 0.9 W
Insulation type wall
outlet
Protection class I or
protection class II
Protection type
wall outlet
IPX4 after proper
installation
Protective areas in rooms with bath
or shower facilities (for installation
examples, see Fig. A)
•
According to national instalation standards
(in Germany DIN VDE 0100-701) electrical
equipment may only be installed in specific
areas in rooms with bathtubs and shower
facilities.
•
Electrical equipment is permitted in the
rooms referred to above if it is protected by
a residual current protective device (RCD)
(in Germany according to DIN EN 61008-1
(VDE 0664-10)).
•
Sockets may only be installed outside safety
areas.
•
Note:
the manufacturer does not approve
the installation of products in protective
area 1.
►
Install the following products only in safety
area 2 or outside the protective areas:
–
Radiator with heating element (DIN
55900 note "coatings for radiators".)
–
Thermostat WFC
–
Wall outlet IPX4 with radio receiver
Installation
Preparatory activities
►
Ensure that a outlet socket (230 V, fuse B16
A) is there within the reach of the cable of
the heating element.
To install a radio receiver, it is advisable to
use a outlet socket with an installation depth
≥ 40 mm and diameter of 68 mm.
The outlet socket must be freely accessible and
may not be in the projection surface of the ra
-
diator.
►
Install radiator and heating element.
Install thermostat and radio receiver/wall
outlet
►
Check the delivery for completeness and
damages (see Fig. B).
►
Install thermostat (see Fig.
C1 / C2).
►
Install radio receiver and wall outlet (see
Fig. D1–D5).
Electrical connection
The device may only be connected by an elec
-
trical specialist.
►
D5: setup electrical connection according to
the diagram Fig. E1 (protection class I) or E2
(protection class II).
•
Designation of the wires:
–
L' = phase heating element (brown)
–
L = phase network (brown)
–
N = neutral heating element (blue)
–
N = neutral network (blue)
–
PE = protective conductor (green / yel
-
low, only for protection class I)
Setup radio communication
►
D6: press the LEARN button on the thermo
-
stat once.
The following message appears on the dis-
play:
Содержание wfc
Страница 42: ...42 C1 1 0 2 2 1 0 A B C2...
Страница 43: ...43 D4 1x 1x 1x 10 11 1x D5 D6 D9 D10 D7 D8 ca 90 mm 9 mm D2 D3 40 mm D1...
Страница 44: ...44 N N L L N N PE L L E2 E1 9 1 9 2 F2 G F1...