- 9-
Parameter
code
Function
Parameter
value
Explanation
d0
Unit of
temperature
F
Fahrenheit(default)
C
Celsius
d1
Operation way
selection
P
By control panel or IR remote
thermostat (default)
r
By 24V universal remote
thermostat
d2
Top temperat
-
ure setting
d3 to 32
℃/
90
℉
The minimum value is d2
(default 32
℃/
90
℉
)
d3
Bottom temp
-
erature setting
16
℃/
60
℉
to d2
The maxi mum value is d3
(default 16
℃/
90
℉
)
COOL/FAN/HEAT MODE OPERATION
PROCEDURE
Control panel:
l
Press the ON/OFF button.
l
Press the HEAT
/
COOL
/
FAN button, select the operation
mode: heat
/
cool
/
fan.
l
Press + or - button, to set your desired temperature. The
setting temperature range is 60-90°F(16-32°C).
l
Press the FAN SPEED button, to set your desired air
flow rate: high/ low
/
auto.
Remote controller:
l
Press the ON/OFF button with the remote controller
pointing toward the packaged terminal air conditioner.
l
Press the MODE button, select the operation mode:
cool/fan/heat.
l
Press + or - button, to set your desired temperature. The
setting temperature range is 61-88
°
F(16-31
°
C).
l
Press the FAN SPEED button, to set your desired air
flow rate:hig/ low/
auto
.
TIMER PROCEDURE
( Remote controller)
When cells are inserted, the present time is automatically
set to AM 0:00.EX.:set to AM10:30.
l
Open the back cover, push the CLK button .The time
indicator is flickering and can set the present time.
l
Press the HOUR button.(set to AM 10:00)
l
Press the MIN button.(set to 30)
l
Press the CLK button again, and then close the back
cover.
NOTE: For some type, this function may be not exist.
SENIOR OPERATION
Under OFF mode, hold [COOL] and [FAN SPEED] two
keys at the same time continuously for
5
seconds. This
time display
‘
d0
’
, indicates that system has entered the
senior operation status.
[COOL]
key is used to switch parameter code and
parameter value;
[+]
or
[-]
keys are used to switch parameter code or set
parameter value;
[ON/OFF]
key is used to save and exit settings.
d4
Indoor tempera
-
ture calibration
-9
℃
to 9
℃
If unit of temperature is changed,
calibration should be done again.
If use the default value, it can be
ignored. (default 0
℃
/
0
℉
)
-9
℉
to 9
℉
d5
Temperature dis
-
play selection
0 or 1
1 indicates displaying room temp
-
erature, 0 for setting point
(default 0)
One setting example: Setting target: d0(C), d1(r),
d2(30
℃
),
d3(18
℃
)
,d4(
-
1
℃
)
,d5(1
).
Step1: hold [COOL] and [FAN SPEED] two keys at the
same time continuously for 5 seconds.
Display:'d0' Step2: short press
[COOL] key. Display:'F'
Step3: short press [+] or [-] key.
Display:'C' (setting d0 has finished)
Step4: short press [COOL] key.
Display:'d0' Step5: short press[+]
key. Display:'d1' Step6: short press
[COOL] key. Display:'P'
Step7: short press[+] or [-] key.
Display:'r' (setting d1 has finished)
Step8: short press [COOL] key.
Display:'d1' Step9: short press[+]
key. Display:'d2' Step10: short
press [COOL] key. Display:'32'
Step11: short press [-] key twice.
Display:'30' (setting d2 has finished)
Step12: short press [COOL] key.
Display:'d2' Step13: short press[+]
key. Display:'d3' Step14: short press
[COOL] key. Display:'16' Step15:
short press [+] key twice. Display:'18'
(setting d3 has finished) Setp16:
short press [COOL] key. Display:'d3'
Step17: short press[+] key.
Display:'d4' Setp18: short press
[COOL] key. Display:'0'