Nr
ERROR MESSAGE
CAUSE
REMEDY
1
and
-
During treatment it is not
possible to distribute the
quantity of liquid per unit of
area set
- Reduce vehicle speed
-
Use nozzles capable of higher delivery
rates
- Increase the maximum working pressure
2
and
-
During treatment it is not
possible to distribute the
quantity of liquid per unit of
area set
- Increase vehicle speed
-
Use nozzles capable of lower delivery
rates
3
and
-
In AUTO mode the Bravo 300
is not receiving the flow-meter
signal
-
Check the connection between the
flow-meter and the Bravo 300
-
In AUTO mode the master
valve switch is on ON but the
control unit is not receiving any
liquid
- Check that the pump is operating
- Check that there is liquid in the tank
4
and
-
In AUTO mode the Bravo 300
is not receiving the speed
sensor signal
-
Check the connection between the speed
sensor and the Bravo 300
-
In AUTO mode the master
valve switch is on ON but the
machine is not moving
- Put the machine in motion
5
and and
-
In AUTO mode the Bravo 300
is not receiving the speed
sensor and flow-meter signals
-
Check the Bravo 300’s connections to
the speed sensor and flow-meter
-
In AUTO mode the master
valve switch is raised but the
machine is at a standstill
-
Put the machine in motion and start up
the pump
6
-
While regulating balancing-
valves, Bravo 300 surveys a
flow-rate, that is too low
-
Check connection between flow-meter
and Bravo 300
- Check flow-meter constant's set-up
7
-
While setting wheel constant,
Bravo 300 didn't get the
correct pulses to calculate the
constant
-
Repeat wheel constant's automatic
set-up
8
-
After changing nozzle type,
balancing valves must be
adjusted
- Adjust balancing valves
9
-
Liquid in tank is below reserve
level
- Fill the tank
?
?
?
?
Operating errors
BRAVO30X monitors all distribution parameters constantly.
In case of a malfunction, the following error messages appear on the
display:
ErO
ErrOr
rEG
?