4673XXX

BRAVO 3XX SERIES COMPUTERS

INSTALLATION

Software rel. 60

Содержание BRAVO 327X

Страница 1: ...4673XXX BRAVO 3XX SERIES COMPUTERS INSTALLATION Software rel 60...

Страница 2: ...This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership Keep it for future reference ARAG reserves the right to mod...

Страница 3: ...ecting the multi pin connector 15 7 2 Connecting the valves 15 7 3 Connecting the sensors and other services 16 8 Accessory connections 17 8 1 Pump Protector 17 8 2 Foam marker 17 8 3 Printer 18 8 4 T...

Страница 4: ...Printer language Menu 90 0 39 9 22 RPM sensor Menu 100 0 40 9 23 Pump Protector Menu 101 0 41 10 Maintenance diagnostics repairs 42 10 1 Fuse replacement 42 10 2 Test functions 43 10 2 1 Speed simulat...

Страница 5: ...nless a particular installation procedure applies only a specific type of computer LIABILITY The installation technician is responsible for implementing the installation procedure in a professio nal m...

Страница 6: ...7003 provides reliable computer diagnostics not of the control unit to which it is connected so as to enable the resolution of any potential problems experienced with the system 3 INTENDED USE The dev...

Страница 7: ...IE 30X BRAVO SERIE 32X Legend 1 Control panel 2 Instruction booklets 3 Speed sensor kit 4a Complete cabling for connection to the valves and sensors 4b Control unit complete with cabling for valves an...

Страница 8: ...ucer F Flow meter P Control valve G Drain valve 1 4 Section valves Tab 2 Assembly diagram for crop sprayers with membrane pump BRAVO 30X Legend A Control panel B Starter key S Speed sensor D Filler pu...

Страница 9: ...r flow meter R Foam marker X Rpm sensor P Control valve 1 5 Section valves Tab 4 Assembly diagram for crop sprayers with membrane pump BRAVO 32X Legend A Control panel B Starter key S Speed sensor D F...

Страница 10: ...collisions as this may damage it or lead to its controls being accidentally actuated install the unit is a visible position within easy reach by hand bear in mind that the computer should not obstruc...

Страница 11: ...5 Remote unit Tab 8 BRAVO 32X Control panel Tab 7 BRAVO 32X Remote unit ITEM CABLING A Section valve unit B Power C Hydraulic valve unit D Control panel X Rpm sensor Pump Protector M Pressure transdu...

Страница 12: ...bolts B Make sure the bracket is securely mounted fit the computer or control unit to it and push it in until it locks in place C Fig 1 5 4 Installing the remote unit Orient the remote unit as indicat...

Страница 13: ...ge or break them Routing the cables to protect against water infiltrations branches in the cable runs must ALWAYS be oriented downwards Fig 2 Fig 2 Fig 3 Fitting the cables to the connection points Do...

Страница 14: ...ected to the unit in two ways direct connection beneath the key 15 54 as shown in Fig 7 connection via relay as shown in Fig 8 If the 15 54 contact services of the starter key can bear a continuous lo...

Страница 15: ...nd turn the collar clockwise until it locks in place 7 2 Connecting the valves All valve connectors must be equipped with gaskets before installation Fig 9 Make sure the gaskets are correctly fitted t...

Страница 16: ...P Control valve G Main valve 1 5 Section valves Tab 13 Use ARAG sensors use of unsuitable sensors or sensors not provided by ARAG automatically voids the warranty ARAG is not liable for damage to the...

Страница 17: ...th the ARAG foam marker control kit code 520004C 100 All information for connecting the foam markers is given in the manual provided with the device ONLY use the ARAG foam marker control kit use of un...

Страница 18: ...er s factory settings are provided on a printout in the package to make another printout of this information hold down the sheet feed button A Table 14 while switching on the printer For any further i...

Страница 19: ...lash on the display 9 1 Pre programming tests and checks Before programming the computer check that all components are correctly installed control unit and sensors the equipment is connected to its po...

Страница 20: ...MAST 60 0 Flow meter 9 16 NO YES Value MENU 60 1 automatic calcu lation 65 0 Pressure transducer 9 17 NO YES Value MENU 65 1 automatic calcu lation 70 0 Type of control 9 18 PRESS FLOW 80 0 Tank volum...

Страница 21: ...not set the working width in crop spraying applications Switches between the display of Distance traveled treatment time treated area Accesses the user programming menu Switches between the display of...

Страница 22: ...odified Control key manual function increases the amount of liquid to be delivered automatic function increases the amount of liquid to be delivered in 10 steps Modification key increases the number o...

Страница 23: ...h down led off The section valve control depend on the type of operation enabled with the computer For full details refer to par 9 15 Type of operation Pressure control valve switch to increase the am...

Страница 24: ...n automatic mode Man ithe computer is operating in manual mode E Speed the value is to the left of the symbol F Nozzle working program in use during treatment G Space covered You can scroll through th...

Страница 25: ...ure transducer T Adjuster valve U Speed sensor V Generic alarm symbol displays in combination with other symbols depending on the fault in question refer to the operating fault paragraph in the user a...

Страница 26: ...increase the brightness 1 Hold down the key 2 Press at the same time to adjust the brightness To decrease the brightness 1 Hold down the key 2 Press at the same time to adjust the brightness 9 9 Acces...

Страница 27: ...modifying the value For the list of displayable data and units of measurement refer to paragraph 11 1 Data and units 9 11 Number of sections Menu 40 0 This parameter sets the number of section valves...

Страница 28: ...nd select Menu 43 0 2 Press in sequence to select the section whose width you wish to set 3 Press to enter section width setting the corresponding value will flash on the display Set the section width...

Страница 29: ...29 English 9 12 1 Technical headings 1 A Section width section valve A 1 B Section width section valve B 2 Boom width Tab 24...

Страница 30: ...select the next number the selected number will flash on the display C Press to confirm the new value D Press to exit without modifying the value 9 14 Type of section valve Menu 50 0 This parameter se...

Страница 31: ...main valve does not affect the opening or closing of the section valves MODEL CODE Standard working SET 467302A 467304A M 467303 467305 467307 46732xx P Tab 25 For further information on the type of o...

Страница 32: ...tran sducer reading and the nozzle data If both the flow meter and the pressure transducer are installed the displayed flow and delivery rates are taken from the device enabled in menu 70 0 Type of c...

Страница 33: ...o launch automatic calculation of the flow meter constant Menu 60 1 2 Press to reset the liquid delivery counter 3 Deliver a known amount of liquid open the main control valve and all section valves b...

Страница 34: ...the number being set B Press to select the next number the selected number will flash on the display C Press to confirm the new value D Press to exit without modifying the value Confirm the actual am...

Страница 35: ...ansducer is present During data modification A Press to confirm the new value B Press to exit without modifying the value 9 17 1 Manual pressure value setting This value indicates the pressure value c...

Страница 36: ...erence device the nozzles are subject to wear which may compromise the reliability of control via the transducer Flow meter control corresponds to programming option Transducer control corresponds to...

Страница 37: ...mputer generates a visual and audible warning during treatment the tank symbol flashes on the display Access programming as described in par 9 9 Access to advanced program ming 1 Press in sequence to...

Страница 38: ...A Press to confirm the new value B Press to exit without modifying the value Filler flow meter constant setting The flow meter constant indicates how many pulses sent to the computer by the flow mete...

Страница 39: ...elect the foam marker control mode During data modification A Press to confirm the new value B Press to exit without modifying the value 9 21 Printer language Menu 90 0 This parameter sets the printou...

Страница 40: ...or is present During data modification A Press to confirm the new value B Press to exit without modifying the value RPM sensor constant setting The RPM sensor constant indicates the number of pulses g...

Страница 41: ...Press in sequence to enable the Pump Protector alarm During data modification A Press to confirm the new value B Press to exit without modifying the value If you have enabled the Pump Protector alarm...

Страница 42: ...itor Bravo 3XX series 10 A Bravo 32X series 1 A Fig 15 Control unit Location of fuses on the control unit Fig 16 Fuse connections F1 10A Hydraulic opening valves and section valves 8 and 9 for Bravo c...

Страница 43: ...ramming for an explanation of the symbols displayed Refer to par 9 4 Using the keys and switches for details on the function of your computer s keys and switches MENU TEST FUNCTIONS Par Software versi...

Страница 44: ...escribed for the access procedure the Bravo 3XX directly launches Menu 190 0 1 Press to activate speed simulation Set the speed you wish to simulate During data modification A Press to modify the valu...

Страница 45: ...question will display on the screen Switches test Move the switch whose operation you wish to test up the symbol for the switch in question will display on the screen Move the switch down the symbol f...

Страница 46: ...and switches 1 2 3 4 6 7 9 10 11 12 13 14 15 16 Tab 27 The following table gives the switches and their symbols as displayed on the screen BRAVO 302X BRAVO 303 BRAVO 304X BRAVO 305 BRAVO 307 BRAVO 32...

Страница 47: ...2 Press to run a print test Fig 17 3 Press to print out the programmed pa rameters Fig 18 during the printout the printer symbol flashes on the display Fig 17 This menu also enables you to print out t...

Страница 48: ...onstants Density factor Nozzle data Units of measurement Number of sections Boom width Nozzle spacing Type of section valve Flow meter Pressure transducer Type of control Tank volume and reserve Foam...

Страница 49: ...puter Enter the test functions as described for the access procedure 1 Press in sequence to scroll through the test function parameters and select Menu 300 The display shows all the information about...

Страница 50: ...ed speed is incorrect even at constant speed Incorrect programming Check the wheel constant setting The delivery volume display is incorrect Incorrect programming Check the wheel constant setting Chec...

Страница 51: ...tor as described in the following table Type of system BRAVO 30X 32X BRAVO 302A 304A A Swap wires 1 and 2 in the main valve connector B Swap wires 1 and 2 in the control valve connector Bravo 30X Cont...

Страница 52: ...pump Legend P Control valve G Main valve 1 5 Section valves TYPE B SYSTEM Crop sprayer with centrifugal pump TYPE C SYSTEM Orchard sprayer Tab 31 For further information refer to the ADDIN file code...

Страница 53: ...m Speed 0 0 99 9 EU EU t km h Speed of the vehicle 0 0 99 9 US mph Delivery 0 1999 EU l ha Quantity of liquid distributed per unit of surface area 0 0 199 9 EU t t ha 0 0 199 9 US gpa Section width 0...

Страница 54: ...ustom blue backlit LCD Power supply 11 14 Vdc 11 14 Vdc Consumption excluding valves 200 mA 1 A Working temperature 0 C 70 C 32 F 158 F 0 C 70 C 32 F 158 F Digital inputs for open collector sensors ma...

Страница 55: ......

Страница 56: ...a Palladio 5 A Tel 0522 622011 Fax 0522 628944 Home page http www aragnet com E Mail info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the c...