5.6
RPM counter
Set RPM counters, if any; by default this field is disabled (Fig. 21): enter constant value to enable
them (Fig. 22);
Set minimum and maximum speed alarms: out of set range the monitor will trigger an alarm
(Fig. 23).
Fig. 21
Fig. 22
RPM Alarms
RPM sensor constant:
indicates the number of pulses output by the sensor,
per revolution of the rotary shaft.
Constant: 0 pls/rev = sensor disabled
Fig. 24
If monitor (Fig. 24) shows an RPM sensor rea-
ding of 0 RPM and it is necessary to manually
work on the moving parts, TURN OFF THE
FARMING MACHINE AND MAKE SURE ALL
MOVING ORGANS ARE ACTUALLY AT A HALT
before attempting any operation.
Fig. 23