AMPLIFIER OPERATION
Figure 2.1 shows the Model 150A400 in pictorial form.
FIGURE 2.1
AMPLIFIER OPERATION
2.2.1 Local Operation
Power-up Sequence:
1.
Connect the input signal to the unit’s
RF INPUT
connector.
The input signal level should be
0dBm maximum.
2.
Connect the load to the unit’s
RF OUTPUT
connector.
3.
Check to see that the
MAIN POWER
switch (circuit breaker) on the unit’s rear panel is set to
the
1
(“on”) position.
4.
Press the
POWER
switch: the front panel vacuum fluorescent display (VFD) should read
POWER ON, STATUS OK
when power is applied.
(NOTE: The amplifier changes state each time the POWER switch is depressed—if the
unit is on when the POWER switch is depressed, it will turn off; if the unit is off when the
POWER switch is depressed, it will turn on.)
5.
In the event of a fault, press the
FAULT/RESET
switch; if the fault does not clear, refer to
subsection
4.3
(“Troubleshooting”) of this manual.
6.
Adjust gain control if necessary.
2.2.2.1
Introduction
This subsection describes remote operation of the Model
150A400
amplifier by utilizing either the
IEEE-488 parallel interface or the RS-232 serial interface and a controlling device, such as a bus
controller or a personal computer (PC).