35 - Manual decalcifying of the function water system
2
1
Pump
Manual decalcifying of the function water system is not necessary when running normally, since there the most used anolyte is itself
a good descaler. Yet catholyte also removes limescale over time. You could have a water flow interference if you produce much
more catholyte than anolyte. If you notice that too little water flows out of the function water outlet, then let 20 liters of anolyte
(Strong Acidic) flow through. If no improvement is noted, a special decalcifying procedure must take place with the pump. This is
pictured in the schematic diagram (1) above. For this you must use the thinner connecting hose of the pump.
1. Connect the end of the soft hose with the pump - as pictured (2) - and the function water outlet. If necessary use the rubber
hose adapter (3) if needed to connect to the pump.
2. Place the acidic wastewater hose into the decalcifying container, as seen in picture 2.
3. Prepare the descaling agent by dissolving 3 tablespoons of citric acid in a liter of warm (max. 50 degrees Celsius) water.
4. After you have filled the container, turn the ionizer ON and set it for 5-10 seconds to STRONG ACID/ALKALINE so that the hose
has no air. Then switch the water supply off immediately.
5. Then plug the pump in (220 V) and wait until the pump produces a cycle. The descaling agent will flow into the device from the
acidic water outlet hose.
6. After 1 hour unplug the pump. Rinse the container and the pump thoroughly with cold water and allow to dry. Before you draw
activated water, let the ionizer run in the PURE mode for about 5 minutes, to remove any remaining descaling agents.
7. If the function water outlet is visibly calcified on the outside, clean it with a coarse sponge which has been immersed in the
decalcifying agent.
Attention:
Please use dishwasher gloves.