background image

10

 

Aquatic

Serenity DriftBath™ Owner's Manual & Installation Guide

ELECTRICAL INSTALLATION:

 INSTALLATION INSTRUCTIONS 

 FRAMING DIAGRAMS

1.  Protect interior of tub throughout installation process.

2.  Framing and supports will vary according to the model and type of installation selected.

3.  Please refer back to the unit's Technical Data sheet for specific dimensions located at www.aquaticbath.com.

Island Drop-In

Alcove-Integral Tiling Flange

Tile Bed

Wood Shim

Wall Stud

Tile

Tub

Tile

100% Silicone

Sealant

1" x 3" Ledger

Tile Bed

Wood Shim

Wall Stud

Tub

Tile bed

100% Silicone

Sealant

Tile

Tub

Alcove-Integral Skirted Models

ISLANDS

ALCOVES

OVAL MODELS

A - 6" x 12" Box-outs
B - Leveled Supports

1" x 3" Ledgers

C - 16" x 16" minimum access 

      on pump end 

CORNER MODELS

A

C

B

LH

AW

RECTANGULAR MODELS

A

C

ID

As Desired

As Desired

DH

IW

B

A

AW

LH

LD

C

C

A

DH

As Desired

As 

Desired

1

A

2

C

A

IW

DH

ID

C

A

DH

A

2

1

C

As 

Desired

As 

Desired

DH

A

LH

B

LD

AW

Note: For Skirt Installation  

disregard front framing   

A

1

=  end drain

A

2

= center drain

LEGEND

AW  Overall Width

DH   Deck Height

ID    Inner Depth

IW   Inner Width

LH    Ledger Height

LD    Ledger Depth

INTEGRALLY SKIRTED MODELS

C

Содержание SERENITY W6AIR6060

Страница 1: ...ications are 3 8 and are subject to change without notice Dimensions listed in inches mm Installer This booklet must be given to the product owner Please add important information below Model ________...

Страница 2: ...n Freestanding 18 Installation of Freestanding Models 19 22 Variable Speed Air Blower Remote Mounting Freestanding 23 24 Serenity 27 Installation 25 26 Remote Control Non Freestanding 27 28 Remote Con...

Страница 3: ...formed ONLY by a qualified electrician and plumber AQUATIC Product Warranty Registration Information 8101 E Kaiser Blvd Suite 200 Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com IMP...

Страница 4: ...ton The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner there is a ground current flowing indicating the possibility of an electr...

Страница 5: ...athing DONT S DO NOT operate the air bath system if The bathtub isn t filled to required levels above air channels You re pregnant until you ve consulted your doctor You re taking medications or drugs...

Страница 6: ...sted and found to comply with the limits for a class B computing device in accordance with the specifications in subpart J of part 15 of the FCC rules which are designed to provide reasonable protecti...

Страница 7: ...sary maintenance as specified in Aquatic Owner s Manual and Installation Guide supplied with the Air Bath 4 Any alteration customization or modification of the Air Bath or its components LIMITATIONS 1...

Страница 8: ...3 Plug in blower control box and run blower for 10 minutes 4 Inspect the tub completely Any defect must be reported to Aquatic prior to installation in order to have it covered by warranty Should ins...

Страница 9: ...rflow leakage is not included in the warranty of this product 3 Tub must rest entirely on its base DO NOT SUPPORT THE BASE OF THE TUB BY THE RIM Aquatic strongly recommends preparing a bed of wet mort...

Страница 10: ...els 100 Silicone Sealant Tile Tile 100 Silicone Sealant 1 x 3 Ledger Tile Bed Tile Bed Wood Shim Wood Shim Wall Stud Wall Stud Tile Tub Tub Tub B A A ACCESS PANEL ON PUMP END C ACCESS PANEL ON PUMP EN...

Страница 11: ...er template will be enclosed with all oval models For the deck cutout scribe on the deck two center lines a major and minor axis Next match the center lines and trace the ellipse Repeat this step thre...

Страница 12: ...old valves see image at right CAUTION Do not overtighten Do not use Teflon Tape PLUMBING 1 After securing tub in place normal waste and overflow water spout and valves are installed per normal plumbin...

Страница 13: ...ectric shock Do not alter the factory installed wiring A licensed electrician must provide the dedicated electrical service protected by a GFCI The location of the GFCI must be accessible for regular...

Страница 14: ...UCTIONS NON FREESTANDING MODELS ELECTRICAL CONNECTIONS Serenity Air Series Component Breakdown OUTPUT INTPUT UP HAUT W D KEYPAD AUX CABLE NEMA PLUG BLOWER KEYPAD LED LIGHT LIGHT CONTROL BOX WATER DETE...

Страница 15: ...NG MODELS ELECTRICAL CONNECTIONS Serenity Air Series Remote Blower Option Component Breakdown OUTPUT INTPUT UP HAUT W D KEYPAD AUX CABLE 25 CABLE 25 EXTENSION 25 NEMA PLUG BLOWER LED LIGHT LIGHT CONTR...

Страница 16: ...NDING MODELS ELECTRICAL CONNECTIONS Serenity Air Series Remote Option Component Breakdown RECEIVER MODULE OUTPUT INTPUT UP HAUT W D KEYPAD AUX NEMA PLUG BLOWER LED LIGHT LIGHT CONTROL BOX WATER DETECT...

Страница 17: ...EYPAD CABLE 25 NEMA PLUG REMOTE CONTROL B IMPORTANT ONE 15 AMP 120 VOLTS CIRCUIT CLASS A NOT TO BE USED WITH THIS OPTION OR RECEIVER MODULE INSTALLATION INSTRUCTIONS FREESTANDING MODELS ELECTRICAL CON...

Страница 18: ...r local code requirements Installing the Blower in a Remote Location The blower can be installed horizontally or vertically The blower intake maybe installed up or down Use PVC 1 1 2 pipe and adapters...

Страница 19: ...four claw feet see Diagram 2A To help prevent the bathtub from shifting we recommend the bathtub legs to be anchored to the floor Also mark the position of the holes to be drilled for the blower air...

Страница 20: ...secure the two anchoring pins 3 8 x 3 lag bolts not supplied to the floor Leave the lag bolts 1 1 2 above floor Wipe off the marker tracings see Diagram 3B 3 Install the overflow and drain on the bath...

Страница 21: ...r pen For information on electrical installation maintenance and care troubleshooting and warranty please refer to the Table of Contents 1 Determine the exact location of the drain air passage and the...

Страница 22: ...ff the marker tracings 3 Install the overflow and drain on the bath Cut pipes to desired length prior to assembly see Diagram 4B Glue the first pipe section PVC 1 1 2 of the air passage to go under th...

Страница 23: ...be accessible at all times Installing the Blower in a Remote Location The blower will come attached to the one way check valve make sure the arrow on the valve is pointing away from the blower The bl...

Страница 24: ...stallation Guide INSTALLATION INSTRUCTIONS FREESTANDING MODELS Key Pad Receiver Blower Flow One Way Valve Key Pad Receiver Blower Flow One Way Valve Serenity 11 13 17 23 24 25 and 26 Serenity 11 13 17...

Страница 25: ...and lay the bath down putting the pipes through the floor Immediately remove any excess silicone 2 Find a location for the Hartford Loop you can mount the Hartford Loop inside a wall or on a wall in a...

Страница 26: ...ee directions anchored to a 2x4 Install so that two inches of loop is above the bottom of the overflow hole Key Pad Receiver Blower One Way Valve 2 Overflow Hole Hartford Loop Flow One Way Valve is Un...

Страница 27: ...Activate the System 1 Plug in the cable as shown in Figure 7B 2 Once everything is connected the remote control is ready for synchronization Synchronization 1 Once the system has been connected the re...

Страница 28: ...place C Mark the position of the magnets with a marker or pencil CAUTION Magnets always have a positive and negative side and will only be attracted to one side Consider this to avoid applying the si...

Страница 29: ...mote Control Only to Activate the System 1 Plug the 25 cable into the blower 2 Install the receiver module 6 10 from point of use 3 Once everything is connected the remote control is ready for synchro...

Страница 30: ...consult a licensed electrician Malfunctions of the air bath controls or the circulating system should be reported to the distributor who supplied the tub Clean up 1 Remove all construction residue an...

Страница 31: ...en in cycles mode increases the speed at which the cycle operates ON WHEN PRESSED 4 SPEED DECREASE 1st Press Press and hold to decrease the blower speed release pressure at the desired speed When in c...

Страница 32: ...raight back to maximum BLINK 3rd Press Returns to maximum speed OFF 3 SPEED INCREASE 1st Press Press and hold to increase the blower speed release pressure at the desired speed When in cycles mode inc...

Страница 33: ...of the fixture using ONLY the proper tool provided for that purpose Do not attempt to remove the lens without the provided tool 4 Replace your LED light replacement LED lights can be obtained from Aq...

Страница 34: ...REMOVAL Minor scratches may be removed by polishing your tub with a non abrasive car polish followed by buffing Deeper scratches can be removed by Sanding with wet 400 grit sandpaper Sanding with wet...

Страница 35: ...minutes to mix cleaner with water Shut blower down and allow cleaner to soak in the bath for approximately two hours Turn on air bath and run for approximately five minutes Turn air bath unit off and...

Страница 36: ...bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia marcescens These bacteria thrive on moisture dust and...

Страница 37: ...soluble form that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water supp...

Страница 38: ...shut off 1 Defective control panel 2 Defective blower 1 Refer to installer dealer Replace control panel 2 Refer to installer dealer Replace control box Air Bath does not function properly while in th...

Страница 39: ...Aquatic 39 Serenity Owner s Manual Installation Guide REPLACEMENT PARTS MAP 3d 11 4a 4b 3b 3c 3a Option 2a 1b 1c 1a 1d 5a 6a 6b Option 2b 2c 2d...

Страница 40: ...AQUATIC Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Suite 200 Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANSER F O D 9005 Rev 04 14...

Страница 41: ...e Dimensions listed in inches mm Installer This booklet must be given to the product owner Please add important information below Model ___________________________________ Purchase Date ______________...

Страница 42: ...stallation Procedures 8 Structural Preparation 9 10 Plumbing 10 Electrical Connections 11 13 Final System Test Clean Up 14 OPERATION INSTRUCTIONS HotSoak Operations 15 Bath side On Off Controls 15 Ins...

Страница 43: ...arranty If you have any questions concerning installation operation maintenance or any other aspect of your Aquatic bath please contact AQUATIC CUSTOMER SERVICE CENTER 800 945 2726 The Troubleshooting...

Страница 44: ...utton The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner there is a ground current flowing indicating the possibility of an elec...

Страница 45: ...lead to unconsciousness with the possibility of drowning Never use the bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcot...

Страница 46: ...e with the specifications in subpart J of part 15 of the FCC rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guara...

Страница 47: ...tSoak is subject to damage during shipping by carriers faulty installation maintenance abuse accident or other damages 2 The HotSoak is installed outdoors 3 The HotSoak is not installed in accordance...

Страница 48: ...e tub completely Any defect must be reported to Aquatic prior to installation in order to have it covered by warranty Should inspection indicate any damage or leaks do not install the bath Damage or l...

Страница 49: ...oduct WARNING Factory skirts do not allow for blocking up of the tub base All blocking must be solid and provide uniform support to the tub base 3 Tub must rest entirely on the base DO NOT SUPPORT THE...

Страница 50: ...nd bead of silicone between the first course of tile and the bath deck PLUMBING 1 After securing tub in place normal waste and overflow water spout and valves are installed per normal plumbing procedu...

Страница 51: ...require a GFCI BONDING WIRE Connect a 8 bare copper bonding wire from the pump motor heater to the cold water plumbing or other suitable ground Grounding is required For built in and custom units ins...

Страница 52: ...20V SINGLE POLE BREAKER WITH GROUND FAULT CIRCUIT INTERRUPTER CLASS A ONE 20 AMP 120 VOLT CIRCUIT NEMA PLUG PUMP CONTROL BOX KEYPAD OUTPUT INTPUT UP HAUT W D KEYPAD AUX PUMP NEMA PLUG ON OFF PUMP BUTT...

Страница 53: ...herapy LED MAIN BREAKER PANEL 120V 240V 60Hz NEMA PLUG LIGHT CONTROL BOX PUMP CONTROL BOX NEMA PLUG KEYPAD OUTPUT INTPUT UP HAUT W D KEYPAD AUX B OUTPUT INTPUT UP HAUT W D KEYPAD AUX C LED LIGHT NEMA...

Страница 54: ...ensed electrician Malfunctions of the pump motor heater electronic controls or the circulating system should be reported to the distributor who supplied the bathtub Clean up 1 Remove all construction...

Страница 55: ...d WARNING Prolonged Immersions in Hot Water May Induce Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 9...

Страница 56: ...TALLATION OF ELECTRONIC ON OFF TIMER CONTROL 1 Plug the On Off Timer Control into a dedicated 120 volt minimum 20 Amp outlet Speed Timer Box 2 Wait 10 20 seconds for self calibration before you depres...

Страница 57: ...s can be obtained from Aquatic NOTE Do not twist LED light into socket Use gentle pressure and push LED light into place OPERATION INSTRUCTIONS KeyPad Functions 1 On Off Pump 1st Press The pump starts...

Страница 58: ...facturer with the product Repeated use may be necessary SUPER SYSTEMS CLEAN PLUS does not replace the necessity to purge your HotSoak system at least twice a month with a low foaming detergent and ble...

Страница 59: ...ly distributed in soil food and also in animals The best solution to keep these surfaces free from the bacterial film is continual cleaning A chlorine containing compound is the best cleaner Avoid abr...

Страница 60: ...water and follow their suggestions for treatment If you are on an individual well you need to contact a water treatment company to test your water and suggest solutions if a problem is present 3 Trea...

Страница 61: ...rotector trips 1 Low voltage 2 Inadequate ventilation 3 Wiring too small 1 Contact your electrician 2 Refer to installer dealer 3 Contact your electrician Pump delivers no water 1 Leakage of air into...

Страница 62: ...STATE HOTSOAK 3A 8501CONTROL CONTROL BOX TMS W P ON OFF 4A OPTION 8500PAD KEYPAD KIT TMS TIMER LIGHT 5A OPTION 8500CONTROL CONTROL BOX CHROMATHERAPY 120V 5B OPTION 8020LIGHTS CHROMATHERAPY 20LEDS BULB...

Страница 63: ...Aquatic 23 Serenity HotSoak Owner s Manual Installation Guide 4a 5a Option 5b 5c Option 5d Option 2a 1a 1b 1c REPLACEMENT PARTS MAP 3a 6a...

Страница 64: ...Fax On Demand System Toll Free 877 618 7024 8101 E Kaiser Blvd Suite 200 Anaheim CA 92808 800 945 2726 Fax 866 544 5353 www aquaticbath com 8MANHSK F O D 9004 REV 04 14...

Страница 65: ...DriftBath INSTALLER This booklet must be given to the product owner Read all instructions before proceeding All specifications are 3 8 and are subject to change without notice Dimensions listed in inc...

Страница 66: ...ON INSTRUCTIONS Pre Installation Instructions 7 8 Structural Preparation 9 Framing Diagrams 10 Deck Cutouts 11 Plumbing 12 Electrical Installation 12 DriftBath with Chromatherapy LED Lights 13 OPERATI...

Страница 67: ...ONLY by a licensed electrician and plumber AQUATIC Product Warranty Registration Information Customer Service 800 945 2726 aquaticbath com IMPORTANT To activate Product Warranty please register with...

Страница 68: ...ted by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt p...

Страница 69: ...l use may lead to unconsciousness with the possibility of drowning Never use the whirlpool while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators h...

Страница 70: ...ns in subpart J of part 15 of the FCC rules which are designed to provide reasonable protection against such interference in a residential installation However there is no guarantee that interference...

Страница 71: ...r the bath is installed is not covered under the warranty To Inspect 1 Place the tub in an area where it may be drained after testing 2 Fill the tub with clean water to the overflow and allow to stand...

Страница 72: ...quietness Please ensure the following The floor structure is adequate to support the installation For quieter operation and heat retention conservation the walls surrounding the tub may be insulated...

Страница 73: ...re a bed of wet mortar in area where tub is to be installed Carefully level unit ensuring that uniform support is given to all areas of the base and no portion of the lip is bearing weight 4 Frame out...

Страница 74: ...Tub Tile 100 Silicone Sealant 1 x 3 Ledger Tile Bed Wood Shim Wall Stud Tub Tile bed 100 Silicone Sealant Tile Tub Alcove Integral Skirted Models ISLANDS ALCOVES OVAL MODELS A 6 x 12 Box outs B Level...

Страница 75: ...re to match the dotted center line on the template with the center line on the plywood Trace again to outline Quadrant 2 Repeat until the remaining quadrants of the cutout have been traced CORNER MODE...

Страница 76: ...aquaticbath com ELECTRICAL INSTALLATION WARNING ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED LOCALLY CERTIFIED ELECTRICIAN IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL COD...

Страница 77: ...LUG PUMP LIGHT CONTROL BOX PUMP CONTROL BOX NEMA PLUG KEYPAD OUTPUT INTPUT UP HAUT W D KEYPAD AUX B OUTPUT INTPUT UP HAUT W D KEYPAD AUX C LED LIGHTS IMPORTANT 15A 120V DOUBLE POLE BREAKER WITH GROUND...

Страница 78: ...eive heat 2 failure to recognize the need to exit the tub 3 unawareness of impending hazard 4 fetal damage in pregnant women 5 physical inability to exit the tub 6 unconsciousness resulting in the dan...

Страница 79: ...TEMS CLEAN PLUS does not replace the necessity to purge your DriftBath system at least once a month with a low foaming detergent and bleach Surface Cleaning Use common household non abrasive cleaners...

Страница 80: ...ies of bacteria causing the problem would require lengthy and costly laboratory testing however most experts believe the bacteria responsible is Serratia Marcescens These bacteria thrive on moisture d...

Страница 81: ...m that is especially noticeable with white tubs If high manganese in the water is present you may also notice black stains on white laundry If this occurs you need to contact the water supplier to det...

Страница 82: ...ian Pump delivers no water 1 Leakage of air into suction system 2 Impeller clogged 1 Check suction screen for clogs 2 Clean and unclog Low pump capacity 1 Suction or discharge line partly plugged 2 Pu...

Страница 83: ...Aquatic 19 Serenity DriftBath Owner s Manual Installation Guide REPLACEMENT PARTS MAP 2a 1b 1a 3a 3b 5 7 5a 8a 8b 7e 7d 7c 7b 7a 4c 4a 4b 4d 4e 4f 4 3 2 6a 6c 6b 6d 6 1 1c 1d 1e...

Страница 84: ...TING DRIFTBATH 4C 1 5 SUCTION ELBOW DRIFTBATH 4D 8409005FTG 0 5 90 DEG ST ELBOW 4E 8050PIPE 0 5 PVC PIPE 4F 1119SLIP 1 5 POP CHECK VALVE 5A 8112LIGHTWH BI 9 LED HIGH BRIGHT LIGHT WH or BI 6A 1106TFIT...

Страница 85: ...to damage during shipping by carriers faulty installation maintenance abuse accident or other damages 2 The tub is installed outdoors 3 The tub is not installed in accordance with standard industry pr...

Страница 86: ......

Страница 87: ......

Страница 88: ...Customer Service 800 945 2726 aquaticbath com 8MANDBTH 01 17...

Страница 89: ...3rd Press Returns to maximum speed 5 ON OFF LIGHT 1st Press Light ON WHITE 2nd Press Light OFF Turn OFF and ON within 3 seconds the light will change to SLOW RAINBOW CYCLE FAST RAINBOW CYCLE TURQUOIS...

Отзывы: