30 Aquatic
Serenity Owner's Manual & Installation Guide
INSTALLATION INSTRUCTIONS
FINAL SYSTEM TEST & CLEAN-UP
System Test
To test system, follow these steps in order listed:
1. Fill clean tub with water to a minimum of 4” above the air channels.
2. To test the Ground-Fault Circuit-Interrupter (GFCI), push the test button. The GFCI should interrupt power.
Push the reset button. Power should be resorted. If the GFCI fails to operate in this manner, there is a
ground current flowing, indicating the possibility of an electric shock. Do not use this unit. Disconnect the
unit and have the problem corrected by a licensed electrician before using.
3. Push on/off button on the air bath unit.
4. Allow system to run a full 10 minutes.
5. Through access door or removable skirt, check for leaks in air bath plumbing system. Make sure half-
union at blower is hand-tight. If leakage is occurring at any other points, notify distributor.
6. If any electrical malfunctions occur, immediately unplug the unit and consult a licensed electrician.
Malfunctions of the air bath controls or the circulating system should be reported to the distributor who
supplied the tub.
Clean-up
1. Remove all construction residue and foreign materials. Wipe unit clean with a damp rag, otherwise
staining may occur.
2. Plaster may be removed by scraping with the edge of a piece of wood or rigid plastic. DO NOT use
metal scraper. For spots left by plaster or grout: rub lightly with a liquid detergent (Spic-N-Span® or
similar) on a damp cloth or sponge.
3.
DO NOT
use abrasive cleaners, scouring powders, steel wool, wire brushes or anything else that may
harm or dull the surface.
4. Paint, tar or stubborn stains may be removed with paint thinner, turpentine or rubbing alcohol. To avoid
discoloration, cleaners containing petroleum distillate must not remain on surfaces. NEVER use lacquer
thinner or chlorinated solvents.
5. Dulled areas can be restored to a high gloss with white or cream-colored automotive rubbing compound,
followed by application of carnauba wax or white or cream automotive paste wax and buffing.
6. Major gouges require professional repair. Contact Aquatic to arrange factory-authorized repair services.
Содержание SERENITY W6AIR6060
Страница 86: ......
Страница 87: ......
Страница 88: ...Customer Service 800 945 2726 aquaticbath com 8MANDBTH 01 17...