background image

WARNING:

Faucet will leak 
if restrictor is 
not installed

6 — CONNECT TUBING

I: Brass Tee to Manifold “INLET”  

(1/4" white tubing)

 

1

  Take the white tubing leading from the brass tee and insert it into the manifold port 

labeled “INLET”. Remember to push it all the way in until it stops.

II: Manifold to Remineralizer 

(3/8" red tubing included in packaging) 

Insert one end into the manifold port labeled “FAUCET”. 

2

 Insert the other end into the remineralizer port labeled “INLET”.

III: Remineralizer to Faucet 

(3/8" white tubing already attached to faucet) 

 Insert the 3/8" white tubing (that was installed in step 4) from the faucet into the 
remineralizer port labeled “OUTLET”.

IV: Manifold to Tank

 

(3/8" white tubing already attached to tank) 

 Take the white tubing leading from the storage tank and 
insert it into the manifold port labeled “TANK”. Remember 
to push it all the way in until it stops.

V: Air Gap to RO Membrane

 

(1/4" red tubing from faucet) 

Insert restrictor into the end of the red tubing. 

2

 Attach 1/4" red tubing to the 90° elbow until it stops. 

Attach 1/4" 90° elbow to the membrane drain port.

VI: Faucet to Drain Connector

 

(3/8" red tubing from faucet) 

  Take the 3/8" red tubing from faucet and insert it all  

the way into the drain connector.

COLD

HOT

Hose Connections:

 

¼" White  Brass Tee to Manifold

 

3⁄8" Red 

Manifold to Remineralizer

 

3⁄8" White  Remineralizer to Faucet

I

I

II

III

 

3⁄8" White  Manifold to Tank

 

¼" Red 

Membrane to Faucet

 

3⁄8" Red 

Faucet to Drain Connector

IV

V

VI

V

II

IV

III

VI

OptimH2O™

Stage 2

RO Membrane

AQ-RO3-RO

OptimH2O™

OptimH2O™

Remineralizer

AQ-RO3-RM

1

2

3

0.95"

Tube Marking Guide:

(actual size)

Tubing Dont’s

DO NOT cut tubing too short. Always double check 

measurements before cutting.
DO NOT bend or crimp or kink tubing.
DO NOT discard excess tubing.

Tubing Do’s

Insert tubing ALL THE WAY IN to prevent 

leaking. In most cases, up to nearly a full inch.
Wet end of tubing to more easily insert into all 

inlets and outlets.
Cut excess tubing in order to prevent crimping, 

kinks, loops or folds.

Содержание OptimH2O AQ-RO-3

Страница 1: ...ter technology is working for you System tested and certified by NSF International against NSF ANSI Standard 42 53 401 and conforms to NSF protocol P473 for reduction of claims specified on the Perfor...

Страница 2: ...aucet hole to ensure there will be enough 3 8 tubing available for both connections Wait to cut tubing and follow instructions below 4 Remove system remineralizer and tank from under your sink to begi...

Страница 3: ...RO3 RO OptimH2O OptimH2O A B C D E F OptimH2O OptimH2O OptimH2O OptimH2O OptimH2O OptimH2O OptimH2O A B C 2 1 2 INSTALL SYSTEM MANIFOLD 1 Select an easily accessible area under the sink to mount syste...

Страница 4: ...cet 5 INSTALL RO DRAIN CONNECTOR WARNING CAUTION Be sure that all electrical appliances and outlets are turned off at the circuit breaker before working in the cabinet area Please wear safety glasses...

Страница 5: ...Membrane red tubing from faucet 1 Insert restrictor into the end of the red tubing 2 Attach red tubing to the 90 elbow until it stops 3 Attach 90 elbow to the membrane drain port VI Faucet to Drain C...

Страница 6: ...ing end If there are squarely cut 1 off and re insert Note When RO Filter System is first pressurized water may project from faucet air gap hole until air is passed from RO Filter System Purge 1 Open...

Страница 7: ...the scaling and fouling tendencies of the Feed Water 2 Measured at 50 psi 77 2 F and 717 mg l TDS per NSF ANSI Standard 58 3 Efficiency rating means the percentage of the influent water to the system...

Страница 8: ...y filled flush saturate the remineralizer cartridge by opening up the filter faucet and allowing the purified water to run through the remineralizer for 3 minutes The water may come out cloudy during...

Страница 9: ...oroethylene 0 007 0 083 0 001 99 cis 1 2 dichloroethylene 0 07 0 170 0 0005 99 trans 1 2 dichloroethylene 0 1 0 086 0 001 99 1 2 dichloropropane 0 005 0 080 0 001 99 cis 1 3 dichloropropylene 0 079 0...

Страница 10: ...hibit the exclusion or limit of incidental or consequential damages so the above limitation or exclusion may not apply to you WARRANTY CARD Warranty registration is not required for coverage under the...

Страница 11: ...s to NSF protocol P473 for reduction of claims specified on the Performance Data Sheet and at nsf org The AQ RO 3 system has been tested and certified by NSF International against NSF ANSI Standard 58...

Отзывы: