background image

NEO

MINERAL

CHARGE

CALCIUM & MAGNESIUM

ENRICHED WATER

NEO

Only Aquaguard

®

 

• 

Has the trust of over 15 million mothers*

• 

Is owned by over 1.62 lakh doctors

• 

Has service with 5 kms. range of wherever you are

• 

Has over 21 different technologies to address 21 different water conditions   

   across the country

• 

Is certified by over 135 leading national and international laboratories

• 

Is sold in over 35 countries worldwide

Make sure that your Aquaguard

®

 Neo is installed by a trained Eureka Forbes 

Service Technician only.

1. Input water must be tested for Total Dissolved Solids (TDS) and Total Hardness.

2. Install your Aquaguard

®

 Neo in a dry ventilated place. 

    - Keep it away from direct sunlight, heating devices or areas below freezing  

      temperatures.

    - You can keep it on the kitchen counter or wall-mount it. 

  

    - The purifier should be placed in area which is free of ants/insects/other pests.

3. Ensure that the input tap water temperature is in the range of 10º-40ºC.

    - Avoid installation to a hot water tap as it can damage the filters.

4. Ensure that the input water pressure for Neo RO+UV+MTDS / RO are          

    from 0.3 kg/cm

2

 – 3.0 kg/cm

2

  and Neo UV+UF is from 0.3 kg/cm

2

 – 2.0          

    kg/cm

2

.If the input water pressure is more than specified, installation of a PRV 

    (Pressure Reducing Valve)** is mandatory. If the input water pressure is less     

    than specified, installation of a booster pump** is recommended. 

5. Flush filter thoroughly and independently for 3-5 minutes to remove fine      

    particles present in the filter. This should be done before installation of the unit.

6. After installing, run the purifier for 5-10 minutes and drain this water.

Input water quality usage limitations:

1. If the input water iron content is more than 0.3 mg/litre, use of an iron remover**  

    is recommended as a pre-treatment.

2. If the input water turbidity is more than 5 NTU or comprises colloidal particles,  

    use of a special filter** is required as a pre-filter.

3. If the input water TDS is more than 1,000 ppm (mg/L) or input water hardness is          

    more than 300 ppm (mg/L), use of a Membrane life enhancer** 

    is recommended.

4. Do not install the water purifier if the TDS is more than that prescribed in the  

    technical specifications.

 

MTDS REGULATOR OPERATING PROCEDURE: (Only Applicable for 

RO+UV+MTDS models)

TDS modulator is located inside the product. As per factory setting, it comes in fully 

closed mode. TDS level of output water can be increased by slowly loosening the 

spindle of the TDS modulator (anti-clockwise). Normally a slight quarter turn is 

enough to increase the TDS of the output water. Rotating the spindle in the clockwise 

direction closes the TDS modulator and reduces the level of TDS blending.

Please note that the TDS blending, and its adjustment is dependent upon the level of 

TDS of input water and on the TDS reduction capacity of the RO membrane. TDS 

adjustment should be done by the authorised Eureka Forbes technician only.

*As per Superbrands & Reader’s Digest.

HERE’S HOW YOUR AQUAGUARD

®

 

NEO UV+UF WORKS

**Available at an extra cost.

HYBRID DIVERTER

VALVE

NOTE : THIS IS A SCHEMATIC ILLUSTRATION OF THE PRODUCT TO GIVE A VISUAL SCHEME OF WORKING OF UNITS. 

THIS IS NOT AN ACTUAL ENGINEERING DRAWING OF THE PRODUCT.

PURIFIED WATER

STORAGE TANK

RAW WATER

INLET

FLOAT

DISC

LPS

E-BOILING

QG TUBE

UF CARTRIDGE

11 w- UV LAMP

 I FILTER

FLOW 

 RESTRICTOR 

CHEMI BLOCK

(W

ITH BUILT-IN PARTICLE TRAP FILTER)

SOLENOID

VALVE

AQUAGUARD Neo UV+UF

( WATER FLOW DIAGRAM )

MINERAL CHARGE CART

RIDGE

WHY IS AQUAGUARD

®

 

INSTALLING YOUR AQUAGUARD

® 

NEO

INSTALLING YOUR AQUAGUARD

®  

NEO

Содержание Aquaguard NEO

Страница 1: ...he input water iron content is more than 0 3 mg litre use of an iron remover is recommended as a pre treatment 2 If the input water turbidity is more than 5 NTU or comprises colloidal particles use of a special filter is required as a pre filter 3 If the input water TDS is more than 1 000 ppm mg L or input water hardness is more than 300 ppm mg L use of a Membrane life enhancer is recommended 4 Do...

Страница 2: ... Full Power Service Tank Full HERE S HOW YOUR AQUAGUARD NEO RO WORKS PURIFICATION PROCESS IN YOUR AQUAGUARD NEO RO HERE S HOW YOUR AQUAGUARD RO WORKS Reduces TDS hardness pesticides and heavy metals like arsenic lead and mercury Eliminates microorganisms like bacteria viruses protozoa and cysts i Filter Multi Layered Polypropylene Roving Wound Cartridge Chemi Block with built in Particle Trap Filt...

Страница 3: ...hier for consumption Mineral Charge Cartridge Calcium Magnesium Enriched Water Reduces TDS hardness pesticides and heavy metals like arsenic lead and mercury Eliminates micro organisms like bacteria viruses protozoa and cysts TDS Regulator Mechanical System Adjusts the TDS of purified water to provide healthy water always 1 2 3 4 5 6 7 Power Parameters LED Indication RO UV MTDS Remarks All LEDs Re...

Страница 4: ...vice requirement post installation please contact the company s service centre 5 The company or its authorized agent will be entitled to retain any defective part replaced under the warranty 6 Notwithstanding anything to the contrary contained or implied by this warranty a The company s liability under this warranty shall be limited to the first sale of the goods by the company to the customer and...

Страница 5: ...ll mean the instructions for Installation use and maintenance provided through QR code along with Product supplied by the company 8 EFL reserves the right in its absolute discretion to change alter or discontinue and alter the terms and conditions from time to time without any prior notice 9 Any disputes are subject to Mumbai Jurisdiction only Post warranty 1 The customer may be offered a yearly S...

Отзывы: