14
Generator
To start the GENERATOR, first check that your generator’s fluids are topped off and the raw water
intake is open. The generator controls are located at the lower helm. First pre-heat the generator by
pushing the top switch down for about 20 seconds. Then while still pre-heating lift the start switch. Hold
both switches in that position while the generator catches (about 5-10 seconds). Make sure water and
exhaust is exiting the port side stern.
After generator is running, change your AC distribution switch to generator. Then turn on AC systems
as you would on shore power one system at a time.
To turn the generator off, first take off the load by turning off AC breakers. Then turn off main AC
distribution switch. Let the generator run without a load for about 2-3 minutes to cool down. Lastly kill
the generator by switching generator switch to “off” until it dies.
House (12-volt) System
Four battery banks support 12-volt DC power: 1) Main engine battery (1 8D); 2) Generator start battery
(1 4D); 3 ) house battery bank (2 8D); and 4) Bow thruster (1 8D).
Your 12 volt panel shows all the systems supported by your batteries. Primarily you will be turning on
the breakers for your lights, water pressure, electronics, etc. The one exception is the DC switch for the
Fresh Water Wash Down. This switch is located at the lower right of the AC panel. Bilge pumps
should always be left on (Auto) and are on a separate panel under the main 12 volt panel.