8.1.11.
Start Concurrent Measurement and Request CRC
This command tells the BlackBox to start making a measurement.
Command
Response
<a>CC!
<a><time><nr-values><CR><LF>
<time> is the time in seconds (three digits) until the measurement will be ready
<nr-values> is a two-digit number (“01”-“20”) specifying the number of
measurements that will be returned by a subsequent D0 command
8.1.12.
Additional Concurrent Measurements and Request CRC
This command tells the BlackBox to start making a measurement.
Command
Response
<a>CC<set>!
<a><time><nr-values><CR><LF>
<set> is a digit (“1”-”9”) indicating which set of additional measurements is being
requested
<time> is the time in seconds (three digits) until the measurement will be ready
<nr-values> is a two-digit number (“00”-“20”) specifying the number of
measurements that will be returned by subsequent D commands
8.1.13.
Start Verification
This command can be used to initiate the BlackBox’s self-tests.
Command
Response
<a>V!
<a><time><nr-values><CR><LF>
<time> is the time in seconds (three digits) until the measurement will be ready
<nr-values> is a single digit (“0”-“9”) specifying the number of numerical values that
will be returned by subsequent D commands
8.1.14.
Service Request
The service request is a signal sent by the BlackBox to indicate that a measurement has
been completed and is ready to read.
Service Request
<a><CR><LF>
© 2019 Aquaread Ltd.
www.aquaread.com
Page 20 of 71