AquaTelemetry Instruction Manual
10401-01193 Rev H
10. Appendix 01. Quick Reference Guide
The first two commands are available to all users. All subsequent commands will only
respond to Administrators.
Command
Shorthand
Header
Command
Format
Function
Request Level
LE
N/A
Request current level,
temperature, alert status and
battery voltage.
Request Config
CO
N/A
Request all logging and alerts
configuration.
Request Email
SE
N/A
Request the unit to upload data
log by email immediately.
Set Logging Interval
LO=
HHH:MM
Sets the main logging interval.
Set Log Upload
Interval
UP=
HH:MM
Sets how often the logged data
is uploaded by email.
Set Initial Upload
Time
FI=
HH:MM
Sets the time for the first email
data upload of the day.
Set the Site ID
SI=
Up to 16 ASCII
characters
Sets a unique identifier name
for the deployment site.
Set the Clock Offset
TI=
+/-HH:MM
Add or subtract time from the
clock to correct for daylight
saving time.
Zero the Level
ZE
N/A
Sets the current level as zero.
All subsequent level readings
will be made +/- against this
reference.
Clear Memory
N/A
CLEAR MEMORY
NOW
Clear the unit's memory. No
shorthand. Must be sent in full.
Set Level 1 Alert
L1=
+/-XXXXX
Level 1 alert value in mm.
Set Level 2 Alert
L2=
+/-XXXXX
Level 2 alert value in mm.
Set Level 3 Alert
L3=
+/-XXXXX
Level 3 alert value in mm.
Set Level 4 Alert
L4=
+/-XXXXX
Level 4 alert value in mm.
Set Rate Alert
RA=
+/-XXXXX
Rate alert value in mm/min.
Set Alert Logging
Interval
AL=
HH:MM
Sets the alert testing and
logging interval.
Query Phone Book
N/A
PBXX=?
Requests the phone number
and status from entry XX in the
phone book.
Set Number in Phone
Book
N/A
PBXX=A/UXXXX
XXXXXXXX
Sets the status and phone
number for entry XX in the
phone book. Leave the number
field blank to delete the entry.
© 2020 Aquaread
®
Ltd.
www.aquaread.com
Page 34 of 34