AquaTelemetry Instruction Manual
10401-01193 Rev H
Message 2 contents
Brief explanation
SETTINGS UPDATE
Message heading
SITE = XXXXXXXXXXXXXXXX
Site identifier (default is AquaTel's serial number)
ALERT LOG INTERVAL=H:MM
Shorter logging interval when an alert is active
L1 ALERT =+XXXXX
Alert level 1 in mm
L2 ALERT =+XXXXX
Alert level 2 in mm
L3 ALERT =+XXXXX
Alert level 3 in mm
L4 ALERT =+XXXXX
Alert level 4 in mm
RATE ALERT=+XXXX
Rate of change alert in mm/minute
The reception of these two messages will prove that the SIM card is properly fitted and that
the communication section of the system is working correctly.
The individual settings can be set up to suite your application now, or the setup can be
done at a later date, after installation of the equipment on site.